Water-circulating probes significantly modify lesion length and axon damage in cooled radiofrequency ablations when compared with similar-sized standard radiofrequency probes in rats

Author:

Cobbs AlyssaORCID,Alas Guillermo,Yadav Ruchi,Mayeux Jacques,Eckmann Maxim S,Provenzano David AnthonyORCID,English Arthur W,Washington Alencia,Wang Ruoya

Abstract

IntroductionPreclinical research demonstrated water-cooled radiofrequency (CRF) ablations have a significant impact on structural and functional changes compared to standard radiofrequency (SRF) ablations. Clinical procedures utilizing RF to treat chronic pain conditions also show sustained functional outcomes. We hypothesize that the design of the RF probes plays an important role in interventional procedure success, but it remains unclear which specific design features.MethodsRF ablations were performed in male Lewis rats (n=51) using multiple-sized probes for CRF (17 Ga/2 mm and 17Ga/4 mm) and SRF (22Ga/5 mm, 18Ga/10 mm and 16Ga/10 mm) to evaluate generator energy output, lesion length, axon damage by histology and nerve function analysis via electromyography. To exclude probe design variables beyond size and remain objective, we tested cooled probes with and without water circulation, which resulted in the CRF probe performing like an SRF probe.ResultsConsistent with our previous findings in smaller probes, CRF large probes delivered more energy (p<0.01) and generated multiple zones of thermal damage in sciatic nerves. When the water-circulating feature was turned off, however, energy output (p<0.001) and lesion length (p<0.05) was significantly reduced. CRF probes with the water circulation also featured significantly more axonal disruption, than larger sized SRF probes (p<0.0001).ConclusionsOverall, this data confirms that CRF’s water-circulating technology has a greater impact on energy deposition, lesion length and axon damage compared with SRF ablations. Moreover, results suggest that the structural differences between RF modalities cannot be solely attributed to probe size, and it may shed light on its differences in clinical outcomes.

Publisher

BMJ

Subject

Anesthesiology and Pain Medicine,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司