ObjectivesMRI scoring systems for hand osteoarthritis (HOA) are currently not available. The present work proposes the Oslo HOA MRI (OHOA-MRI) score and examines the intrareader and inter-reader reliability.MethodsRelevant HOA features were included in the initial version of the OHOA-MRI score after literature review and informal group discussions. After a training session and two calibration exercises (with three readers), features with low reliability and/or low prevalence were excluded, and feature definitions/gradings were improved. In the reliability exercise 3 readers independently evaluated MRI scans of distal interphalangeal (DIP) and proximal interphalangeal (PIP) joints in 10 patients with HOA according to the final proposed score. The reading was repeated after 1 week. Intraclass correlation coefficients (ICCs), percentage exact agreement/percentage close agreement (PEA/PCA) and smallest detectable difference were calculated.ResultsThe final proposed OHOA-MRI score includes assessment of synovitis, flexor tenosynovitis, erosions, osteophytes (OPs), joint space narrowing (JSN) and bone marrow lesions (BMLs) on a 0–3 scale, and absence/presence of cysts, malalignment (frontal/sagittal plane), collateral ligaments (CLs) and BMLs at CL insertion sites. Inter-reader reliability was very good for synovitis, erosions, OPs, JSN, malalignment (frontal) and BMLs (ICCs ≥0.83, PCA ≥89%), and good for flexor tenosynovitis (ICC 0.64, PCA 80%) and CL presence (ICC 0.79, PEA 63%). Cysts, malalignment (sagittal) and BMLs at CL insertion sites showed high PEA (≥85%), but poor to moderate ICCs (0.00–0.59). Intrareader reliability was similar. The reliability was generally highest in PIP joints.ConclusionsThe proposed OHOA-MRI score could reliably assess HOA features. However, further validation is needed.

Publisher

BMJ

Subject

General Biochemistry, Genetics and Molecular Biology,Immunology,Immunology and Allergy,Rheumatology

Cited by 87 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3