Abstract
ObjectiveThe NETRA (Near Eye Tool for Refractive Assessment) is a smartphone-based refractive tool that allows for self-evaluation of refractive error. This study investigates the validity of the NETRA with and without cycloplegia to non-cycloplegic subjective refractions (SR).Methods and analysisParticipants underwent NETRA measurements without cycloplegia, and again after the administration of cycloplegia (cyclopentolate hydrochloride 1%). Non-cycloplegic SR were also performed. Variation of refractive measurements in symmetric dioptric power space were investigated using stereo-pair comets, hypothesis tests for variances and means. Bland-Altman plots were applied to better understand validity of the NETRA against non-cycloplegic SR. Coefficients of repeatability and intraclass correlation coefficients were also determined.ResultsThe sample included 22 women (64.7%) and 12 men (35.3%); most were indigenous Africans (52.9%) with mean age and SD of 20.24±1.95 years. Variation of refractive measurements were mainly stigmatic (spherical), and variation of NETRA measurements decreased after cycloplegia. The pre-cycloplegia NETRA measurements (and their means) for the right and left eyes were more negative (myopic) in power than the post-cycloplegia NETRA measurements and means. On average, eyes were approximately 1.25 D more myopic with the NETRA without cycloplegia. With cycloplegia, NETRA results were in closer agreement with non-cycloplegic SR for the same eyes.ConclusionNETRA validity to SR, even in the absence of cycloplegia, suggests the instrument may be useful in geographical regions where self-refractions might be potentially helpful in addressing limitations in eye and vision care.
Reference45 articles.
1. Pamplona V , Modi R , Solaka N . NETRA-G: Towards a subjective self-refraction. In: Frontiers in Optics. Optical Society of America, 2014 (pp.: FW3F–2.
2. Pamplona VF , Mohan A , Oliveira MM . NETRA: Interactive display for estimating refractive errors and focal range. In: ACM SIGGRAPH 2010 papers. NETRA, 2010: 1–8.
3. Pamplona VF . Interactive measurements and tailored displays for optical aberrations of the human eye [Doctorate thesis]. Porto Alegre, The Federal University of Rio Grande do Sul, Brazil, 2012.
4. Comparing Laser Ray Tracing, the Spatially Resolved Refractometer, and the Hartmann-Shack Sensor to Measure the Ocular Wave Aberration
5. Eyenetra inc . NETRA user manual. Cambridge MA, USA: NETRA, 2016. https://www.eyenetra.com/manual/netra.pdf
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献