Dispersive viscosurgical devices demonstrate greater efficacy in protecting corneal endothelium in vitro

Author:

Yildirim Timur MertORCID,Auffarth Gerd U,Son Hyeck-SooORCID,Khoramnia Ramin,Munro Donald John,Merz Patrick R

Abstract

ObjectiveDuring phacoemulsification, the corneal endothelium is protected by an ophthalmic viscosurgical device (OVD). In this in vitro study, we assessed six different OVDs for their effectiveness in protecting the corneal endothelium.Methods and analysisPhacoemulsification was performed in cadaver eyes of young pigs. Five syringe units of six different OVDs were tested (Healon EndoCoat, Viscoat, Methylvisc, Healon, Healon GV, ProVisc). After surgery, the area of endothelium coated with OVD was determined in relation to the total endothelial surface. Additionally, an endothelial cell count was obtained. As a control, an endothelial cell count was obtained from freshly trephined corneas. Statistical analysis was performed using the Mann-Whitney U test and the Spearman correlation.ResultsThe least postoperative endothelial coating and cell count were observed in the cohesive OVDs while the dispersive OVDs showed statistically significant higher values. Healon EndoCoat and Viscoat yielded a coating area of 86 (85–92)% and 85 (85-90)%, respectively. Endothelial cell count was highest in the two dispersive groups with 4065 (3928–4088) cells/mm2 (Methylvisc) and 4032 (4015–4115) cells/mm2 (Viscoat). Endothelial coating area and endothelial cell count correlated statistically significantly.ConclusionDispersive OVDs from this study showed greater adherence to the endothelial surface than the cohesive ones. Furthermore, postoperative endothelial cell counts of corneas treated with dispersive OVDs were higher than of corneas treated with cohesive OVDs. Our in vitro results suggest that dispersive OVDs protect the corneal endothelium better during phacoemulsification than cohesive OVDs.

Funder

Klaus Tschira Stiftung

Publisher

BMJ

Subject

Ophthalmology

Reference17 articles.

1. The effects of prolonged phacoemulsification time on the corneal endothelium;Beesley;Ann Ophthalmol,1986

2. Auffarth GU . Ophthalmic viscoelastic devices (OVD) in ocular surgery. Bremen Germany: UNI-MED-Verlag, 2012.

3. Biofunctionalized lysophosphatidic acid/silk fibroin film for cornea endothelial cell regeneration;Choi;Nanomaterials,2018

4. Corneal endothelial cell coating during phacoemulsification using a new dispersive hyaluronic acid ophthalmic viscosurgical device;Kretz;J Cataract Refract Surg,2014

5. Endothelial Protection and Viscoelastic Retention During Phacoemulsification and Intraocular Lens Implantation

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3