Cataract surgery and environmental sustainability: a comparative analysis of single-use versus reusable cassettes in phacoemulsification

Author:

Kallay Oscar,Sadad Rayane,Zafzafi Ahmed,Motulsky ElieORCID

Abstract

ObjectiveTo compare sustainability, financial implications and surgical efficiency of two phacoemulsification cassette systems for cataract surgery: a machine with single-use cassettes and another with daily, reusable ones.MethodsObservational study involving retrospective cataract surgery data collection at the Centre Médical de l’Alliance, Braine-l’Alleud, Belgium, a tertiary eye care centre. Information on cassette weight, quantities and transport volume was obtained from routine procedures and purchasing records. The costs for each machine were calculated by reviewing the invoices received from the accounting department.ResultsWe found significant differences across comparisons. The reusable cassette machine, when compared with the single-use machine, used 306.7 kg less plastic (75.3% reduction), required 2494 m3less storage per 1000 surgeries (67.7% decrease) and cost €54.16 less per 10 procedures (16.9% reduction). The machine with daily reusable cassettes also exhibited a 7-minute priming time advantage for 10 procedures, reducing downtime between cases.ConclusionsOur findings underscore the benefits of adopting reusable cassette systems: reduced plastic consumption, storage volume and priming time, as well as enhanced efficiency and cost-savings. Healthcare professionals and institutions are encouraged to embrace environmentally conscious initiatives. The use of reusable cassette systems for cataract surgeries offers a pathway to sustainable practices.

Publisher

BMJ

Reference8 articles.

1. Health care's response to climate change: a carbon footprint assessment of the NHS in England

2. The carbon footprint of cataract surgery;Morris;Eye (Lond),2013

3. The carbon footprint of cataract surgery in a French University;Ferrero;J Fr Ophtalmol,2022

4. The carbon footprint of cataract surgery in Wellington;Latta;N Z Med J,2021

5. The carbon footprint of cataract surgery in Spain;Pascual-Prieto;Arch Soc Esp Oftalmol (Engl Ed),2023

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献