First clinical multicenter experience with the new Scepter Mini microballoon catheter

Author:

Vollherbst Dominik FORCID,Chapot RenéORCID,Wallocha MartaORCID,Saatci IsilORCID,Cekirge SaruhanORCID,Rouchaud AymericORCID,Mounayer CharbelORCID,Kocer NaciORCID,Kizilkilic OsmanORCID,Sourour Nader AORCID,Shotar EimadORCID,Psychogios Marios NORCID,Brehm AlexORCID,Bendszus MartinORCID,Möhlenbruch Markus AORCID

Abstract

BackgroundBalloon-assisted techniques can improve the endovascular treatment of cerebrospinal vascular malformations. The aim of this study was to report the first clinical multicenter experience with the new Scepter Mini dual-lumen microballoon catheter.MethodsPatients with cerebral or spinal vascular malformations treated with the Scepter Mini at seven European neurovascular centers were retrospectively reviewed. Clinical data, angiographic features of the vascular malformations, procedural parameters including the type of application, navigability, technical failures, complications and embolization success were assessed.ResultsThe usage of 34 Scepter Mini microballoon catheters in 20 patients was analyzed. Most treated malformations (80.0%) were cerebral arteriovenous malformations. Four different applications were reported: embolization via Scepter Mini (n=23, 67.6%), balloon-occlusion with simultaneous embolization via a second microcatheter (n=3, 8.8%), diagnostic angiography with simultaneous balloon-inflation for flow arrest (n=4, 11.8%), and navigation support (n=4, 11.8%). The mean diameter of the blood vessels in which the Scepter Mini was inflated was 1.9±0.5 mm. The navigability of the Scepter Mini was rated as ‘easy’ or ‘very easy’ in 88.2% of cases. Complete occlusion of the malformation was achieved in 60.9% of cases. Technical failures occurred in 4/23 embolization procedures, and all were related to insufficient stability of the balloon within the vessel. No complications related to the Scepter Mini were observed, while unrelated complications occurred in three patients (15.0%).ConclusionsThe Scepter Mini is a promising new device for balloon-assisted embolization of cerebrospinal vascular malformations via small feeders. Beyond embolization, the Scepter Mini can also be used for other applications, such as superselective flow arrest and navigation support.

Publisher

BMJ

Subject

Neurology (clinical),General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3