Intracranial venous sinus stenosis: hemodynamic assessment with two-dimensional parametric parenchymal blood flow software on digital subtraction angiography

Author:

Almadidy Zayed,Brunozzi Denise,Nelson Jessica,Baumgart John,Atwal Gursant,Alaraj Ali

Abstract

ObjectiveIntracranial venous sinus stenosis (IVSS) is the most common finding associated with idiopathic intracranial hypertension. A pressure gradient >8–10 mm Hg across the stenosis is considered hemodynamically significant, and typically responds to endovascular stent treatment. Here we assess the venous hemodynamics with two-dimensional (2D) parametric parenchymal blood flow software (Siemens-Healthineers, Forchheim, Germany) and its ability to predict significant IVSS.MethodsPatients with IVSS treated at our institution between 2013 and 2018 were retrospectively reviewed. Measurements of contrast transit time on DSA were calculated with 2D parametric parenchymal blood flow software. Values were obtained proximally and distally to the stenotic region. Venous Stenosis Index (VSI) was defined as the ratio of the area under the curve (AUC) in the pre-stenotic vessel to the AUC in the post-stenotic vessel. VSI was compared between the stenotic and control groups at baseline, and before and after stent deployment in the stenotic group. The accuracy of VSI was assessed using the non-parametric receiver operating characteristic (ROC) curve.Results11 patients with IVSS treated with venous stent deployment were included. Patients in the control group were similar in age, gender, and absence of major comorbidities. VSI in the IVSS group was significantly higher at baseline compared with the control group (1.42 vs 0.97, p=0.01). Area under the ROC was 0.82. After stent deployment, VSI decreased significantly compared with baseline (1.04 vs 1.42, p<0.01).Conclusion2D parametric parenchymal blood flow software is a useful tool which can accurately evaluate significant hemodynamic venous stenosis without intracranial catheterization, added radiation exposure, additional contrast injection, and periprocedural risks.

Funder

Siemens Healthineers

Publisher

BMJ

Subject

Neurology (clinical),General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3