Device size selection can enhance Y-stentrieving efficacy and safety as a rescue strategy in stroke thrombectomy

Author:

Cabral Lucas ScottaORCID,Mont’Alverne Francisco,Silva Henrique CoelhoORCID,Passos Filho Paulo Eloy,Magalhães Pedro S C,Bianchin Marino Muxfeldt,Nogueira Raul G

Abstract

BackgroundDespite advancements in stroke treatment, refractory clots are relatively common, prompting the exploration of alternative techniques. Bifurcation occlusions pose specific intraprocedural challenges, occasionally dealt with by two stentrievers deployed in Y-configuration. Previous studies have portrayed this strategy as feasible, yet little is known about its safety and efficacy, and how to best select retrievers.ObjectiveTo determine whether device selection influences the efficacy and safety of Y-stentrieving.MethodsWe performed a multicentric, retrospective analysis of patients undergoing Y-stentrieving rescue for bifurcation occlusions. Demographics, devices, procedural metrics, neurological severity, reperfusion, disability, and safety were assessed.ResultsY-configuration stents were used as a rescue maneuver after 2.16±1.5 failed attempts with other techniques in 20 patients. Successful reperfusion (modified Thrombolysis in Cerebral Infarction score 2b–3) was achieved in 70% of patients after the first Y-stentrieving attempt. The first stentriever more often had a larger diameter (5.15±0.92 vs 3.67±0.57 mm, p=0.017) and longer length (33.12±5.78 vs 20.67±1.15 mm, p=0.002) in successfully reperfused cases. Also, the diameter of the first device was associated with both any parenchymal (6.0 vs 4.71±0.99 mm, p=0.045) and symptomatic (6.0 vs 4.86±1.02 mm, p<0.001) hemorrhages. Exact logistic regression demonstrated that a longer length first stentriever independently predicted better angiographic outcomes (OR=1.26, p=0.036), and a 6 mm diameter first stentriever independently predicted more intracranial hemorrhages (OR=15.28, p=0.044). No periprocedural mortality was recorded.ConclusionY-stentrieving is an effective and safe bail-out strategy for refractory bifurcation clots. Longer stents may promote better angiographic outcomes, whereas avoidance of disproportionately large retrievers may mitigate intracranial hemorrhage. Future studies should account for these factors when evaluating alternative stentriever techniques.

Publisher

BMJ

Subject

Neurology (clinical),General Medicine,Surgery

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3