Abstract
ObjectiveVenous sinus stenting (VSS) is a safe and effective treatment for idiopathic intracranial hypertension (IIH) with angiographic venous sinus stenosis. However, predictors of stent-adjacent stenosis (SAS) remain poorly defined.MethodsWe performed a retrospective review of 47 patients with IIH and intracranial venous stenosis who underwent VSS with pre- and post-stent venography. Patient characteristics, treatments and outcomes were reviewed. Changes in pressure gradient after VSS were classified according to pattern of gradient resolution into types I–III.ResultsType I gradient resolution, in which mean venous pressure (MVP) in the transverse sinus (TS) decreases towards MVP in the sigmoid sinus (SS), occurred in 18 patients (38.3%). Type II gradient resolution pattern, in which SS MVP increases towards that in the TS, occurred in 7patients (14.9%). Type III pattern, in which MVP equilibrates to a middle value, occurred in 22patients (46.8%). SAS occurred in 0%, 28.6%, and 22.7% of patients in types I, II and III, respectively. Compared with patients with type I gradient resolution, SAS was more common in those with type II (p=0.0181) and type III (p=0.0306) patterns.ConclusionsThe pattern of change in the trans-stenosis venous pressure gradient may be predictive of SAS and is a useful tool for classifying the response of the venous obstruction to stenting. A type I pattern appears to represent the ideal response to VSS. Some patients with type II and III changes, particularly if they have other predictors of recurrent stenosis, may benefit from longer initial stent constructs.
Subject
Clinical Neurology,General Medicine,Surgery
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献