Effect of coronary flow on intracoronary alteplase: a prespecified analysis from a randomised trial

Author:

Maznyczka Annette MarieORCID,McCartney Peter,Duklas Patrycja,McEntegart Margaret,Oldroyd Keith GORCID,Greenwood John P,Muir Douglas,Chowdhary Saqib,Gershlick Anthony H,Appleby Clare,Eteiba Hany,Cotton James,Wragg Andrew,Curzen NickORCID,Tait R Campbell,MacFarlane Peter,Welsh PaulORCID,Sattar NaveedORCID,Petrie Mark C,Ford Ian,Fox Keith A A,McConnachie AlexORCID,Berry ColinORCID

Abstract

ObjectivesPersistently impaired culprit artery flow (<TIMI 3) during primary percutaneous coronary intervention is a surrogate for failed myocardial perfusion. We evaluated the effects of intracoronary alteplase according to TIMI flow grade immediately preceding drug administration.MethodsIn T-TIME (trial of low-dose adjunctive alTeplase during primary PCI), patients ≤6 hours from onset of ST-elevation myocardial infarction (STEMI) were randomised to placebo, alteplase 10 mg or alteplase 20 mg, administered by infusion into the culprit artery, pre-stenting. In this prespecified, secondary analysis, coronary flow was assessed angiographically at the point immediately before drug administration. Microvascular obstruction, myocardial haemorrhage and infarct size were assessed by cardiovascular magnetic resonance (CMR) at 2–7 days and 3 months.ResultsTIMI flow was assessed after first treatment (balloon angioplasty/aspiration thrombectomy), immediately pre-drug administration, in 421 participants (mean age 61±10 years, 85% male) and was 3, 2 or 1 in 267, 134 and 19 participants respectively. In patients with TIMI flow ≤2 pre-drug, there was higher incidence of microvascular obstruction with alteplase (alteplase 20 mg (53.1%) and 10 mg (59.5%) combined versus placebo (34.1%); OR=2.47 (95% CI 1.16 to 5.22, p=0.018) interaction p=0.005) and higher incidence of myocardial haemorrhage (alteplase 20 mg (53.1%) and 10 mg (57.9%) combined vs placebo (27.5%); OR=3.26 (95% CI 1.44 to 7.36, p=0.004) interaction p=0.001). These effects were not observed in participants with TIMI 3 flow pre-drug. There were no interactions between TIMI flow pre-drug, alteplase and 3-month CMR findings.ConclusionIn patients with impaired culprit artery flow (<TIMI 3) after initial balloon angioplasty/thrombus aspiration, intracoronary alteplase was associated with increased presence of microvascular obstruction and myocardial haemorrhage.Trial registration numberNCT02257294.

Funder

British Heart Foundation

Publisher

BMJ

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3