Comparing a novel Catfish flow restoration device and the Solitaire stent retriever for thrombectomy revascularisation in emergent largevessel occlusion stroke: a prospective randomised controlled study

Author:

Luo GangORCID,Yan Xiaoyan,Xiao Guodong,Wei Liping,Nai bi jiang Ya li kun,Ma Rongyao,Chen Wenhuo,Fang Chun,Zhou Zhiming,Wan Jieqing,Peng Ya,Zhang Guilian,Zhao Junfeng,Li Li,Yuan Haicheng,Wu JinORCID,Li Bing,Zhang Fan,Cheng Yuhong,Gao Feng,Miao Zhongrong

Abstract

BackgroundThe Catfish stent retriever is a newly developed mechanical thrombectomy device for rapid recanalisation in emergent large vessel occlusion (ELVO) stroke. The current trial aimed to assess whether the Catfish stent retriever is non-inferior to the Solitaire stent retriever in terms of outcomes in ELVO stroke.MethodsThis was a randomised, prospective, parallel-group, multicentre, open-label, non-inferiority study conducted at 18 sites in China. The primary outcome was the proportion of cases with successful recanalisation (modified thrombolysis in cerebral infarction score of 2b or 3) following the procedure. Secondary efficacy outcomes included the National Institutes of Health Stroke Scale scores at 24 hours and 7 days or discharge if earlier, time from artery puncture to successful recanalisation and good clinical outcome (modified Rankin scale score ≤2) at 90 days. Safety outcomes included symptomatic intracranial haemorrhage, all cause-death and severe adverse events at 90 days.ResultsBetween 3 March 2019 and 5 June 2021, 118 and 120 patients were randomly allocated to the Catfish and Solitaire groups, respectively. The primary endpoint after all endovascular procedures was non-inferior in the Catfish group (88.5%, 100/113) than in the Solitaire group (87.7%, 100/114), with a rate difference (RD) of 0.78% (95% CI –7.64 to –9.20; p=0.001). Sensitivity analysis only considering the per-protocol set also yielded similar results, with an RD of 0.83% (95% CI –7.03 to –8.70; p<0.001). Additionally, the proportions of cases with good clinical outcomes (47.8% vs 50.0%, p=0.739) and all-cause death rates (17.7% vs 18.8%, p=0.700) were similar in both groups at 90 days.ConclusionsThe Catfish stent retriever is an effective and safe device for endovascular recanalisation in ELVO stroke.Trial registration numberNCT03820882.

Funder

National Key R&D Program

Beijing Hospitals Authority Youth Programme

Beijing Natural Science Foundation

JSSK Neurocare Medical Co., Ltd.

Publisher

BMJ

Subject

Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3