Abstract
A 53-year-old man with dysphagia underwent uneventful placement of a percutaneous endoscopic gastrostomy (PEG) tube for long-term enteral feeding access. 11 hours after the procedure, it was discovered that he had accidentally dislodged the feeding tube. On physical examination, he was found to have a benign abdomen without evidence of peritonitis or sepsis. He was observed overnight with serial abdominal examinations and nasogastric decompression. In the morning, he was taken back to the endoscopy suite where endoscopic clips were employed to close the gastric wall defect and a PEG tube was replaced at an adjacent site. The patient was fed 24 hours thereafter and discharged from the hospital 48 hours after the procedure. Early accidental removal of a PEG tube in patients without sepsis or peritonitis can be safely treated with simultaneous endoscopic closure of the gastrotomy and PEG tube replacement, resulting in earlier enteral feeding and shorter hospital stay.
Reference30 articles.
1. National trends in gastrointestinal access procedures: an analysis of Medicare services provided by radiologists and other specialists;Duszak;J Vasc Interv Radiol,2003
2. Complications related to percutaneous endoscopic gastrostomy (PEG) tubes. A comprehensive clinical review;Schrag;J Gastrointestin Liver Dis,2007
3. Percutaneous endoscopic gastrostomy: indications, technique, complications and management;Rahnemai-Azar;World J Gastroenterol,2014
4. Complications of and controversies associated with percutaneous endoscopic gastrostomy: report of a case and literature review;Potack;Medscape J Med,2008
5. Early accidental dislodgement of PEG tubes;Marshall;J Clin Gastroenterol,1994
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献