Author:
Narang Sumeet,Joshi Jayateertha,Vasudevarao Sunil Baikadi,Rao Suchetha
Abstract
A 7-year-old girl presented to the emergency room (ER) with alleged history of aspiration of a toy magnet. The challenge was to safely extract the foreign body. A bronchoscopic approach with forceps, or Dormia basket, or Fogarty catheter, was considered, but these approaches had disadvantages, such as slipping or impaction of the object, and oxygen desaturation. Applying principles of removal of intraocular metallic objects in ophthalmologic surgery using magnetism, the object was removed with the help of another larger surface magnet. The location of the foreign body was confirmed by bronchoscopy. A Fogarty catheter was introduced distal to the object, under bronchoscopic guidance. A strong surface magnet was then placed on the surface of the chest and under C-arm guidance, the object was moved from the bronchus to the trachea. Once at the vocal cords, the Fogarty catheter was inflated to prevent it from slipping back and the magnet was extracted using forceps.
Reference4 articles.
1. Small magnet aspiration as a pediatric emergency: a case report;Xu;Int J Clin Exp Med,2015
2. Bronchoscopic Airway Foreign Body Extraction without Using Optical Forceps;Hegde;J Indian Assoc Pediatr Surg,2018
3. Thoracoscopic foreign body removal and repair of bronchus intermedius following injury during failed bronchoscopic retrieval;Asaf;Lung India,2017
4. V. On the Use of an Electro-Magnet for Removal of a Foreign Body from a Bronchus;Hosmer;Ann Surg,1904
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献