Author:
Steele Lloyd,Flowers David,Coles Simon,Gibbs Paul
Abstract
A 51-year-old man presented with a swollen left arm and unilateral pulsatile tinnitus 2 weeks after a left upper arm polytetrafluoroethylene graft was created for haemodialysis access. A fistulogram of the left upper arm showed a central venous stenosis and significant retrograde flow up the left internal jugular vein. Percutaneous transluminal angioplasty was attempted unsuccessfully and fistula ligation was subsequently performed. This led to immediate resolution of the tinnitus. The venous stenosis was likely secondary to a cardiac resynchronisation therapy defibrillator, which had been removed 1 year previously. Central venous stenosis is a common but often asymptomatic complication of a cardiac device, with the exception of patients with upper extremity arteriovenous fistulas, who frequently develop symptomatic venous hypertension. This generally presents with ipsilateral arm swelling and/or high venous pressures during dialysis. To our knowledge, this is the first report of pulsatile tinnitus arising in this context.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献