Chest pain following permanent pacemaker insertion… a case of pneumopericardium due to atrial lead perforation

Author:

Aktaa Suleman,Fatania Kavi,Gains Claire,White Hazel

Abstract

Permanent pacemaker (PPM) implantation is an increasingly common procedure with complication rate estimated between 3% and 6%. Cardiac perforation by pacemaker lead(s) is rare, but a previous study has shown that it is probably an underdiagnosed complication. We are presenting a case of a patient who presented 5 days after PPM insertion with new-onset pleuritic chest pain. She had a normal chest X-ray (CXR), and acceptable pacing checks. However, a CT scan of the chest showed pneumopericardium and pneumothorax secondary to atrial lead perforation. The pain only settled by replacing the atrial lead. A repeat chest CT scan a few months later showed complete resolution of the pneumopericardium and pneumothorax. We believe that cardiac perforation can be easily missed if associated with normal CXR and acceptable pacing parameters. Unexplained chest pain following PPM insertion might be the only clue for such complication, although it might not always be present.

Publisher

BMJ

Subject

General Medicine

Reference11 articles.

1. The 11th annual report for the National Cardiac Rhythm Management Devices Audit, April 2015 – March 2016, published on 14th February, 2017. http://www.ucl.ac.uk/nicor/audits/cardiacrhythm/documents/annual-reports/crm-devicesnational-audit-report-2015-16_v2.

2. Implantable cardioverter defibrillators: risks accompany the life-saving benefits;Atwater;Heart,2012

3. Temporal trends in quality of care among recipients of implantable cardioverter-defibrillators: insights from the National Cardiovascular Data Registry;Dodson;Circulation,2014

4. Gender and outcomes after primary prevention implantable cardioverter-defibrillator implantation: Findings from the National Cardiovascular Data Registry (NCDR);Russo;Am Heart J,2015

5. [Retrospective analysis on the clinical features and management of acute and subacute right ventricular perforation by pacemaker lead];Dai;Zhonghua Xin Xue Guan Bing Za Zhi,2013

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3