Abstract
The flow–volume loop (FVL) analysis is typically helpful in establishing the diagnosis of airway obstruction caused by endobronchial lesions. In this report, we describe a patient with emphysema and tobacco abuse who presented with chronic dry cough and severe chronic obstructive pulmonary disease (COPD) refractory to standard therapy. The initial FVL showed a relatively normal forced expiratory peak flow shape followed by a smooth flattening of the expiratory curve on spirometry, a pattern consistent with distal airway obstruction as seen in severe asthma or COPD. The patient was later found to have a large endotracheal mass. This atypical presentation, along with the unusual FVL, led to a significant delay in the diagnosis of the tracheal mass. A high level of suspicion is needed to diagnose variable intrathoracic airway obstruction in patients presenting with severe asthma or COPD who fail to improve with standard therapy.
Reference15 articles.
1. Interpretative strategies for lung function tests;Pellegrino;Eur Respir J,2005
2. Interpreting spirometry: the basics;Parker;Otolaryngol Clin North Am,2014
3. Inspiratory flow-volume curve evaluation for detecting upper airway disease;Sterner;Respir Care,2009
4. Tracheal and bronchial tumors;Varela;J Thorac Dis,2016
5. Incidence of noncutaneous melanomas in the U.S;McLaughlin;Cancer,2005