Comparison of hydrosonography and transvaginal ultrasonography in the detection of intracavitary pathologies in women with abnormal uterine bleeding

Author:

Guven M. A.,Bese T.,Demirkiran F.

Abstract

BackgroundThe aim of the study was to compare the accuracy of hydrosonography with that of transvaginal ultrasonography in detection of intracavitary pathologies in patients with history of abnormal uterine bleeding.Study designProspective, randomized, and unblinded study.Material and methodsA total of 197 women (n = 130 premenopausal and n = 67 postmenopausal) aged between 23 and 71 years (mean age 45.7 ± 8.9) presenting with a history of abnormal uterine bleeding were included into the study. Hydrosonography was carried out by experienced gynecologists, on the same setting in an outpatient clinic immediately after the performance of transvaginal sonography. The finally obtained surgical-pathologic findings were compared with the results obtained from transvaginal sonography and hydrosonography. Sensitivity, specificity, positive, and negative predictive values were calculated for each procedure.ResultsThe surgical-pathologic examination confirmed normal physiologic endometrium in 50 (48%) of 104 women who were said to have normal endometrium on transvaginal sonography. Seventy (75%) of 93 women diagnosed of intracavitary pathologies on transvaginal sonography were confirmed by surgical-pathologic findings. The sensitivity, specificity, positive predictive value, and negative predictive value of transvaginal sonography in the detection of intracavitary pathology were 56, 68, 75, and 48%, respectively. Surgical-pathologic results revealed intracavitary pathologies in 23 (30%) of 76 women who were said to have normal endometrium on hydrosonography. Among 121 women diagnosed of intracavitary pathologies on hydrosonography, 101 (81%) women were confirmed after histological evaluation of the surgical specimens. The sensitivity, specificity, positive predictive value, and negative predictive value of hydrosonography in the detection of intracavitary pathology were 81, 73, 83, and 70%, respectively. Sensitivity and negative predictive value were significantly higher with hydrosonography. There were five cases of endometrial malignancy in which one of the case of malignancy was on polyp and two cases of endometrial hyperplasia with atypia which were not stated on sonographic results.ConclusionHydrosonography is more accurate than transvaginal ultrasography in the detection of intracavitary pathologies in women with abnormal uterine bleeding.

Publisher

BMJ

Subject

Obstetrics and Gynecology,Oncology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3