Low-dose CT hounsfield units: a reliable methodology for assessing vertebral bone density in radiographic axial spondyloarthritis

Author:

Marques Mary LucyORCID,Pereira da Silva Nuno,van der Heijde DesiréeORCID,Reijnierse Monique,Baraliakos XenofonORCID,Braun JuergenORCID,van Gaalen Floris AORCID,Ramiro SofiaORCID

Abstract

ObjectiveStudying vertebral bone loss in radiographic axial spondyloarthritis (r-axSpA) has been challenging due to ectopic bone formation. We cross-sectionally analysed low-dose CT (ldCT) trabecular bone density Hounsfield units (HU) measurements and calculated inter-reader reliability at the vertebral level in patients with r-axSpA.MethodsLdCT scans of 50 patients with r-axSpA from the sensitive imaging in ankylosing spondylitis study, a multicentre 2-year prospective cohort were included. Trabecular bone HU taken from a region of interest at the centre of each vertebra (C3-L5) were independently assessed by two trained readers. HU mean (SD), and range were provided at the vertebral level, for each reader and centre separately. Inter-reader reliability and agreement were assessed using intraclass correlation coefficients (ICC; single measurements, absolute agreement, two-way mixed effects models); smallest detectable difference and Bland-Altman plots.ResultsOverall, 1100 vertebrae were assessed by each reader. HU values decreased from cranial to caudal vertebrae. For readers 1 and 2 respectively, the highest mean (SD) HU value was obtained at C3 (354(106) and 355(108)), and the lowest at L3 (153(65) and 150 (65)). Inter-reader reliability was excellent (ICC(2,1):0.89 to 1.00). SDD varied from 4 to 8. For most vertebrae, reader 1 scored somewhat higher than reader 2 (mean difference of scores ranging from −0.6 to 2.9 HU). Bland-Altman plots showed homoscedasticity.ConclusionLdCT measurement of HU is a feasible method to assess vertebral bone density in r-axSpA with excellent inter-reader reliability from C3 to L5. These results warrant further validation and longitudinal assessment of reliability.

Funder

Dutch Rheumatism Association

Fundação para a Ciência e Tecnologia

Publisher

BMJ

Subject

Immunology,Immunology and Allergy,Rheumatology

Reference30 articles.

1. Axial spondyloarthritis

2. Loss and gain of bone in spondyloarthritis: what drives these opposing clinical features?;Clunie;Ther Adv Musculoskelet Dis,2020

3. Lim MJ , Kang KY . A contemporary view of the diagnosis of osteoporosis in patients with axial spondyloarthritis. Front Med 2020;7.doi:10.3389/fmed.2020.569449

4. The Fascinating Paradox of Osteoporosis in Axial Spondyloarthropathy

5. International Atomic Energy Agency . Radiation protection of patients during DXA. Available: https://www.iaea.org/resources/rpop/health-professionals/other-specialities-and-imaging-modalities/dxa-bone-mineral-densitometry/patients#1