Evaluating cross contamination on a shared ventilator

Author:

Doukas Donald JosephORCID,Paladino Lorenzo,Hanuscin Christopher,McMahon Jonathan,Quale John,Bhatt Isha,Eason Julie,Silverberg Mark

Abstract

BackgroundDisasters have the potential to cause critical shortages of life-saving equipment. It has been postulated that during patient surge, multiple individuals could be maintained on a single ventilator. This was supported by a previous trial that showed one ventilator could support four sheep. The goal of our study is to investigate if cross contamination of pathological agents occurs between individuals on a shared ventilator with strategically placed antimicrobial filters.MethodsA multipatient ventilator circuit was assembled using four sterile, parallel standard tubing circuits attached to four 2 L anaesthesia bags, each representing a simulated patient. Each ‘patient’ was attached to a Heat and Moisture Exchange filter. An additional bacterial/viral filter was attached to each expiratory limb. ‘Patient-Lung’ number 1 was inoculated with an isolate of Serratia marcescens, and the circuit was run for 24 hours. Each ‘lung’ and three points in the expiratory limb tubing were washed with broth and cultured. All cultures were incubated for 48 hours with subcultures performed at 24 hours.ResultsWashed cultures of patient 2, 3 and 4 failed to demonstrate growth of S. marcescens. Cultures of the distal expiratory tubing, expiratory limb connector and expiratory limb prefilter tubing yielded no growth of S. marcescens at 24 or 48 hours.ConclusionBased on this circuit configuration, it is plausible to maintain four individuals on a single ventilator for 24 hours without fear of cross contamination.

Publisher

BMJ

Subject

Critical Care and Intensive Care Medicine,General Medicine,Emergency Medicine

Reference10 articles.

1. A Single Ventilator for Multiple Simulated Patients to Meet Disaster Surge

2. Increasing ventilator surge capacity in disasters: Ventilation of four adult-human-sized sheep on a single ventilator with a modified circuit

3. Menes K , Tintinalli J , Plaster L . How one Las Vegas ED saved hundreds of lives after the worst mass shooting in U.S. history, 2017. Available: https://epmonthly.com/article/not-heroes-wear-capes-one-las-vegas-ed-saved-hundreds-lives-worst-mass-shooting-u-s-history/

4. Health and Human Services Washington DC COVID-19 Co-Ventilation Task force . Co-Ventilating patients during a critical ventilator shortage: a method for implementation, 2020. Hhs and FemA website. Available: https://www.hhs.gov/sites/default/files/optimizing-ventilator-use-during-covid19-pandemic.pdf [Accessed 11/17/2020].

5. SCCM . Joint statement on multiple patients per ventilator, 2020. Available: https://www.sccm.org/Disaster/Joint-Statement-on-Multiple-Patients-Per-Ventilato

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献