Performance of a prehospital HEART score in patients with possible myocardial infarction: a prospective evaluation

Author:

Cooper Jamie GORCID,Ferguson James,Donaldson Lorna A,Black Kim M M,Livock Kate J,Horrill Judith L,Davidson Elaine M,Scott Neil W,Lee Amanda J,Fujisawa Takeshi,Lee Kuan Ken,Anand Atul,Shah Anoop S V,Mills Nicholas L

Abstract

IntroductionThe History, Electrocardiogram (ECG), Age, Risk Factors and Troponin (HEART) score is commonly used to risk stratify patients with possible myocardial infarction as low risk or high risk in the Emergency Department (ED). Whether the HEART score can be used by paramedics to guide care were high-sensitivity cardiac troponin testing available in a prehospital setting is uncertain.MethodsIn a prespecified secondary analysis of a prospective cohort study where paramedics enrolled patients with suspected myocardial infarction, a paramedic Heart, ECG, Age, Risk Factors (HEAR) score was recorded contemporaneously, and a prehospital blood sample was obtained for subsequent cardiac troponin testing. HEART and modified HEART scores were derived using laboratory contemporary and high-sensitivity cardiac troponin I assays. HEART and modified HEART scores of ≤3 and ≥7 were applied to define low-risk and high-risk patients, and performance was evaluated for an outcome of major adverse cardiac events (MACEs) at 30 days.ResultsBetween November 2014 and April 2018, 1054 patients were recruited, of whom 960 (mean 64 (SD 15) years, 42% women) were eligible for analysis and 255 (26%) experienced a MACE at 30 days. A HEART score of ≤3 identified 279 (29%) as low risk with a negative predictive value of 93.5% (95% CI 90.0% to 95.9%) for the contemporary assay and 91.4% (95% CI 87.5% to 94.2%) for the high-sensitivity assay. A modified HEART score of ≤3 using the limit of detection of the high-sensitivity assay identified 194 (20%) patients as low risk with a negative predictive value of 95.9% (95% CI 92.1% to 97.9%). A HEART score of ≥7 using either assay gave a lower positive predictive value than using the upper reference limit of either cardiac troponin assay alone.ConclusionsA HEART score derived by paramedics in the prehospital setting, even when modified to harness the precision of a high-sensitivity assay, does not allow safe rule-out of myocardial infarction or enhanced rule-in compared with cardiac troponin testing alone.

Funder

NHS Grampian Endowment Fund

Digital Health and Care Innovation Centre

Publisher

BMJ

Subject

Critical Care and Intensive Care Medicine,General Medicine,Emergency Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3