Insufficient quality of public automated external defibrillator recordings in the greater Paris area, a descriptive study

Author:

Derkenne ClémentORCID,Jost DanielORCID,Haruel Pierre Alexandre,Kedzierewicz Romain,Frattini Benoit,Frédéric LemoineORCID,Diegelmann Pascal,Gouze Jeremy,Roquet Florian,Travers Stéphane,Bihannic Rene,Prunet Bertrand,

Abstract

BackgroundWestern countries report a significant increase in the proportion of patients who experience out-of-hospital cardiac arrests (OHCAs) and benefit from a public automated external defibrillator (pAED) before the arrival of rescue teams. However, recordings of devices recovered after resuscitation are of variable quality. Analysis of these data may inform decisions of whether to implement an internal defibrillator for survivors, and provide useful information about the performance of pAED algorithms and the actions of bystanders.ObjectiveTo investigate the quality of the information recorded by pAEDs during OHCAs in the Paris area.MethodspAED files used for some of the 8629 OHCAs that occurred in the greater Paris area between 1 January 2017 and 31 April 2019 on the day of the arrest were collected. The presence and accuracy of 23 factors required to interpret the recording was noted, including readability of the ECG, the presence of an impedance curve and the accuracy of the date and time. The recordings were analysed to assess the diagnostic and therapeutic performance of the pAEDs used.ResultsA total of 258 patients with an OHCA received assistance from a pAED, and 182 recordings were recovered. The pAEDs were made by 12 different manufacturers. Data extraction required eight different transmission modes and 16 software programmes; recordings were of highly heterogeneous quality. Two per cent of the recordings were of such poor quality that they were not interpretable. Among the 98% remaining, only 43% included a thoracic impedance curve, 34% the intensity of the shocks delivered and 8% the patient name. The date and time were accurate in 68% and 48% of recordings, respectively. The pAEDs had 87.6% (95% CI 83.7% to 91.0%) sensitivity and 99.5% (99.5% to 99.5%) specificity for defibrillating shockable rhythms (positive predictive value 98.2% (96.4% to 99.0%), negative predictive value 96.4% (95.3% to 96.8%)). The absence of important variables prevented the analysis of approximately half of the inappropriate decisions made by pAEDs.ConclusionCollection of pAED recordings is a major challenge. Their analysis is compromised by heterogeneity and poor quality (incomplete maintenance records, patient details and logs). AED recordings are currently the most relevant resource to track pAED performance and bystander practices. The quality of these recordings needs to improve.

Funder

Paris Fire Brigade

Publisher

BMJ

Subject

Critical Care and Intensive Care Medicine,General Medicine,Emergency Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3