Abstract
Platelet-rich plasma (PRP) has become increasingly popular in pain medicine with hopes of becoming a safe, effective alternative to routine treatments. However, given its autologous nature, PRP injectate may differ depending on the specific manufacturer and protocol. Currently, there is no standardization of reporting protocol. This systematic review compiles and standardizes values on PRP preparation and final product composition of platelets, white cell count, and growth factors for ease of comparison. On review of 876 studies, 13 studies were selected according to our inclusion criteria. Data from 33 PRP systems and protocols were extracted and standardized. Overall, PRP final product concentrations as well as PRP preparation protocols varied widely between systems. However, platelet concentration was directly correlated with both volume of blood collected and device centrifugal force. In conclusion, there is a large heterogeneity between PRP separation systems that must be resolved for proper study of this promising treatment.
Subject
Anesthesiology and Pain Medicine,General Medicine
Cited by
95 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献