Compressed 3D and 2D digital images versus standard 3D slide film for the evaluation of glaucomatous optic nerve features

Author:

Sandhu Simrenjeet,Rudnisky Chris,Arora Sourabh,Kassam Faazil,Douglas Gordon,Edwards Marianne C,Verstraten Karin,Wong Beatrice,Damji Karim F

Abstract

SynopsisClinicians can feel confident compressed three-dimensional digital (3DD) and two-dimensional digital (2DD) imaging evaluating important features of glaucomatous disc damage is comparable to the previous gold standard of stereoscopic slide film photography, supporting the use of digital imaging for teleglaucoma applications.Background/aimsTo compare the sensitivity and specificity of 3DD and 2DD photography with stereo slide film in detecting glaucomatous optic nerve head features.MethodsThis prospective, multireader validation study imaged and compressed glaucomatous, suspicious or normal optic nerves using a ratio of 16:1 into 3DD and 2DD (1024×1280 pixels) and compared both to stereo slide film. The primary outcome was vertical cup-to-disc ratio (VCDR) and secondary outcomes, including disc haemorrhage and notching, were also evaluated. Each format was graded randomly by four glaucoma specialists. A protocol was implemented for harmonising data including consensus-based interpretation as needed.ResultsThere were 192 eyes imaged with each format. The mean VCDR for slide, 3DD and 2DD was 0.59±0.20, 0.60±0.18 and 0.62±0.17, respectively. The agreement of VCDR for 3DD versus film was κ=0.781 and for 2DD versus film was κ=0.69. Sensitivity (95.2%), specificity (95.2%) and area under the curve (AUC; 0.953) of 3DD imaging to detect notching were better (p=0.03) than for 2DD (90.5%; 88.6%; AUC=0.895). Similarly, sensitivity (77.8%), specificity (98.9%) and AUC (0.883) of 3DD to detect disc haemorrhage were better (p=0.049) than for 2DD (44.4%; 99.5%; AUC=0.72). There was no difference between 3DD and 2DD imaging in detecting disc tilt (p=0.7), peripapillary atrophy (p=0.16), grey crescent (p=0.1) or pallor (p=0.43), although 3D detected sloping better (p=0.013).ConclusionsBoth 3DD and 2DD imaging demonstrates excellent reproducibility in comparison to stereo slide film with experts evaluating VCDR, notching and disc haemorrhage. 3DD in this study was slightly more accurate than 2DD for evaluating disc haemorrhage, notching and sloping.

Funder

Canadian National Institute for the Blind

Capital Health

Publisher

BMJ

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3