Abstract
AimTo evaluate the applicability of imaging devices (spectral-domain optical coherence tomography (Cirrus SD-OCT), scanning laser polarimetry (GDx) and scanning laser ophthalmoscopy (Heidelberg Retinal Tomograph, HRT3)) for glaucoma screening in a middle-aged unselected population.MethodsParticipants of the population-based Northern Finland Birth Cohort Eye Study, aged 45 to 49 years, underwent a comprehensive eye examination including modern imaging with five methods (retinal nerve fibre layer (RNFL) and macular ganglion cell layer +inner plexiform layer (GCIPL) analysis and their combination with SD-OCT, GDx and HRT). The performance of the automated classification of the imaging devices was assessed using a clinical glaucoma diagnosis as reference, that is, the ‘2 out of 3’ rule based on the evaluation of optic nerve head and RNFL photographs and visual fields.ResultsWe examined 6060 eyes of 3039 subjects; in the clinical evaluation, glaucomatous damage was found in 33 subjects (1.1%) in 43 eyes. The following sensitivities were obtained; RNFL analysis (53%), GCIPL analysis (50%), OCT combination analysis (61%), GDx (56%) and HRT (31%) with corresponding specificities of 95%, 92%, 90%, 88% and 96%. The area under the curve values were 0.76, 0.73, 0.75, 0.75 and 0.73, respectively. Post-test probabilities of glaucoma after positive imaging finding with each of these methods in this unselected population were 11%, 7%, 6%, 5% and 7%, respectively.ConclusionScreening capabilities of the OCT, GDx and HRT were rather similar. The accuracy of all evaluated parameters was only moderate and thus screening with these parameters alone is not reliable.
Funder
Glaukooma Tukisäätiö Lux Foundation, Finland
Competitive State Research Financing of the Expert Responsibility Area of Tampere University Hospital, Finland
Oulu University Hospital
European Regional Development Fund
Oulun Yliopisto
Silmäsäätiö Foundation, Finland
Subject
Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology
Reference27 articles.
1. [Principles and practice of mass screening for disease];Wilson;Bol Oficina Sanit Panam,1968
2. Weinreb R , Healey P , Topouzis F . Glaucoma screening; world glaucoma association consensus series 5 . Amsterdam, The Netherlands: Kugler Publications, 2018.
3. Screening for prevention of optic nerve damage due to chronic open angle glaucoma;Hatt;Cochrane Database Syst Rev,2006
4. Screening Tests for Detecting Open-Angle Glaucoma: Systematic Review and Meta-analysis
5. Screening for Open Angle Glaucoma: Systematic Review of Cost-effectiveness Studies
Cited by
23 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献