Interdevice comparison of retinal sensitivity assessments in a healthy population: the CenterVue MAIA and the Nidek MP-3 microperimeters

Author:

Balasubramanian Siva,Uji Akihito,Lei Jianqin,Velaga Swetha,Nittala Muneeswar,Sadda SriniVas

Abstract

BackgroundTo compare and correlate the retinal sensitivity measurements obtained with Nidek Microperimetry-3 (MP-3) and the CenterVue Macular Integrity Assessment (MAIA) microperimeters among healthy subjects.MethodsIn this prospective comparative study, 31 eyes of 23 subjects underwent complete ophthalmological examination including retinal sensitivity assessments using two microperimeters, the MP-3 (Nidek Technologies) and the MAIA (CenterVue). The mean retinal sensitivity (dB) and its corresponding luminance (asb) and contrast (log units) were analysed between the two instruments. The interdevice reproducibility and level of agreement between the sensitivity values of the devices were assessed.ResultsThe mean retinal sensitivity (dB) measured by the MP-3 (25.02±1.06 dB, range: 20.90–26.70) was significantly (p<0.0001) lower compared with the MAIA (30.68±0.74 dB, range: 28–31.84). The luminosity levels were significantly (p<0.0001) higher with the MP3 (7.75±1.31 asb, range: 6.44–9.06) compared with the MAIA (0.92±0.14 asb, range: 0.78–1.06). The contrast sensitivity was significantly higher for the MP-3 (0.94±0.33 log units, range: 0.61–1.27) compared with the MAIA (0.23±0.03 log units, range: 0.20–0.26). Despite these absolute differences, the intraclass coefficient was 0.85 (95% CI 0.70 to 0.92) between the two devices after applying a standard correction factor to each data point (MAIA sensitivity=MP-3 sensitivity+5.65) with a mean difference between MAIA and MP-3 of 0.01.ConclusionRetinal sensitivity measures higher, but luminance and contrast sensitivity measure lower for MAIA-generated values compared with the MP-3. The relationships, however, appeared fairly consistent, and application of a standard correction factor allowed the data to be inter-related, at least for normal eyes.

Publisher

BMJ

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

Reference16 articles.

1.  Maia - The New Frontier of Microperimetry. Accessed 16 Aug 16.

2. Fundus-driven perimetry (microperimetry) compared to conventional static automated perimetry: similarities, differences, and clinical applications;Acton;Can J Ophthalmol,2013

3. Microperimetry and OCT findings in female carriers of choroideremia;Thobani;Ophthalmic Genet,2010

4. Intrasession Test–Retest Variability of Microperimetry in Age-Related Macular Degeneration

5. Clinicaltrials.gov. https://clinicaltrials.gov/ct2/results?term=microperimetry&pg=4 (accessed 16 Aug 16).

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3