‘Van Herick Plus’: a modified grading scheme for the assessment of peripheral anterior chamber depth and angle

Author:

Sihota Ramanjit,Kamble Neha,Sharma Ajay K,Bhari Anju,Gupta Amisha,Midha Neha,Selvan Harathy,Dada Tanuj,Gupta Viney,Pandey Ravindra M

Abstract

AimTo evaluate the accuracy of a new, modified grading scheme involving a short vertical slit beam, at the inferior angle for peripheral anterior chamber depth (PAC) and angle estimation and its correlation with anterior segment optical coherence tomography (ASOCT).MethodsA cross-sectional study of consecutive phakic patients, above 40 years of age, was performed. Using a short, vertical slit beam not reaching the pupil, the inferior angle at the sclerolimbal junction was evaluated, photographed and assessed by a ratio of peripheral anterior chamber depth to peripheral corneal thickness (PAC:PCT) and iridocorneal angle (ICA) on ImageJ software. The inferior angle at the same meridian was also recorded on ASOCT.ResultsBased on the PAC:PCT ratio, the subjects were divided into four groups: I (<1/4), II (1/4-1/2), III (>1/2–1) and IV (>1). The clinically assessed angle by short vertical slit beam correlated well with ASOCT values, trabecular-iris angle (TIA) (r=0.918; p<0.001) and scleral spur angle (r=0.903, p<0.001). The mean difference between ICA and TIA on ASOCT was 0.7970; 95% limits of agreement:−5.7670 to 7.3610 (±1.96 SD). For angles graded narrow on ASOCT (TIA <200), using a cut-off of peripheral PAC:PCT <1/4, the area under the curve was 0.918 with a sensitivity of 85.2% and a specificity of 88.2%. There was good agreement between ImageJ parameters with those assessed subjectively on photograph of the slit beam examination by a glaucoma fellow (weighted kappa=0.74) as compared with a general ophthalmologist, where there was moderate agreement (weighted kappa=0.57).ConclusionA short, vertical slit lamp beam evaluation at the inferior angle is an easy and relatively accurate method for both peripheral anterior chamber depth and angle assessment. It correlated well with ASOCT and can be used as a more reliable screening tool to identify eyes with possibly occludable angles.

Publisher

BMJ

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3