Effect of fundus tracking on structure–function relationship in glaucoma

Author:

Montesano GiovanniORCID,Rossetti Luca M,McKendrick Allison M,Turpin Andrew,Fogagnolo Paolo,Oddone Francesco,Lanzetta Paolo,Perdicchi Andrea,Johnson Chris A,Brusini Paolo,Garway-Heath David F,Crabb David P

Abstract

AimsTo investigate the effect of fundus tracking perimetry on structure–function relationship in glaucoma.MethodsPerimetric data were acquired with the Humphrey Field Analyzer (HFA) and the Compass fundus perimeter (CMP, equipped with fundus tracking). We included data from 696 eyes from 360 healthy people and 711 eyes from 434 patients with glaucoma from the original study, for which the circumpapillary retinal nerve fibre layer optical coherence tomography scan (Cp-RNFL) was available. We explored the structure–function relationship using both global indices (mean deviation and average Cp-RNFL thickness loss) and anatomically defined visual field clusters comparing the R2 values from mixed-effect models. We then measured the diagnostic ability of a combined Structure Function Index (SFI) using perimetric data from either perimeter. The comparisons were based on partial receiver operating characteristic curves with a minimum specificity of 75% and their areas under the curve.ResultsThe R2 for the global structure–function relationship was 0.50 for the CMP and 0.48 for the HFA. When visual field clusters were included in the model, the R2 was 0.29 for CMP and 0.30 for HFA. Overall, the discrimination ability of the SFI was not significantly higher than the Cp-RNFL for either the CMP (p=0.07) or the HFA (p=0.14). However, it was significantly better in eyes with perimetric damage (p<0.001), in which the CMP-SFI performed significantly better than the HFA-SFI (p=0.03).ConclusionsStructure–function relationship is similar between the two perimeters. Fundus tracking might improve discrimination ability with a combined SFI.Trial registration numberISRCTN13800424.

Publisher

BMJ

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3