Usefulness of data augmentation for visual field trend analyses in patients with glaucoma

Author:

Asaoka RyoORCID,Murata Hiroshi,Matsuura MasatoORCID,Fujino YuriORCID,Miki Atsuya,Tanito MasakiORCID,Mizoue Shiro,Mori Kazuhiko,Suzuki Katsuyoshi,Yamashita Takehiro,Kashiwagi Kenji,Shoji Nobuyuki

Abstract

AimTo investigate the usefulness of data augmentation in visual field (VF) trend analyses in patients with glaucoma.MethodThis study included 6380 VFs from 638 eyes of 417 patients with open-angle glaucoma. Various affine transformations were applied to augment the VF data: (1) rotation, (2) scaling, (3) vertical and horizontal shift and (4) a combination of these different transformations. Using pointwise linear regression (PLR), the total deviation (TD) values of a patient’s 10th VF were predicted using TD values from shorter VF series (from first to third VFs (VF1–3) to first to ninth VFs (VF1–9)) with and without VF data augmentation, and the root mean squared error (RMSE) was calculated.ResultsWith PLR, mean RMSE without VF augmentation averaged from 3.95 (VF1–3) to 19.01 (VF1–9) dB. The RMSE was significantly improved by applying the different transformations: (1) rotation (from VF1–3 to VF1–7), (2) scaling (from VF1–3 to VF1–6), (3) vertical and horizontal shifts (from VF1–3 to VF1–4) and (iv) a combination of these (from VF1–3 to VF1–7). Progression rates in VF1–10 had better agreement with those in shorter VF series when a combination of affine transformation was applied. The differences in rates were between 1.9 (VF1–3) and 0.39 (VF1–9) dB if augmentation was used, which was significantly smaller than that observed when augmentation was not applied (from 2.6 with VF1–3 to 0.26 dB with VF1–9).ConclusionIt is useful to apply VF data augmentation techniques when predicting future VF progression in glaucoma using PLR, especially with short VF series.

Funder

Japan Science and Technology Agency

Suzuken Memorial Foundation

the Daiichi Sankyo Foundation of Life Science

the Ministry of Education, Culture, Sports, Science and Technology of Japan

Publisher

BMJ

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

Reference34 articles.

1. Differential Light Threshold in Automated Static Perimetry

2. Differential Light Threshold

3. False-negative responses in glaucoma perimetry: indicators of patient performance or test reliability?;Bengtsson;Invest Ophthalmol Vis Sci,2000

4. Influence of fixation accuracy on threshold variability in patients with open angle glaucoma;Henson;Invest Ophthalmol Vis Sci,1996

5. On the accuracy of measuring rates of visual field change in glaucoma