Abstract
BackgroundFlow diverters are the first-line treatment for specific intracranial aneurysms (iA). Surpass Evolve (SE) is a new-generation 64-wire flow diverter with a high braid angle. Current literature on the SE is limited. We aimed to report the first international real-world experience evaluating the safety and effectiveness of the SE.MethodsThe Safety and Effectiveness Assessment of the Surpass Evolve (SEASE) was a multicenter retrospective international post-marketing cohort study including consecutive patients treated with SE for iAs between 2020 and 2022. Demographic, clinical, and angiographic data were collected. Primary effectiveness was independent core lab adjudicated complete occlusion rates (Raymond-Roy Class 1) at last follow-up. Primary safety were major ischemic/hemorrhagic events and mortality.ResultsIn total, 305 patients with 332 aneurysms underwent SE implantation. The patients had a median age of 59 [50-67] years, and 256 (83.9%) were female. The baseline modified Rankin scale score was 0–2 in 291 patients (96.7%). Most aneurysms were unruptured (285, 93.4%) and saccular (309, 93.1%). Previous treatment was present in 76 (22.9%) patients. The median aneurysm size was 5.1 [3.4–9.0] mm, and the median neck width was 3.6 [2.7–5.1] mm. Most aneurysms were in the internal carotid artery C6 ophthalmic segment (126, 38.0%), followed by the communicating segment (58, 17.5%). At median 10.2 [6.4–12.9] months follow-up, 233 (73.0%) aneurysms achieved complete occlusion. After adjusting for confounders, complete occlusion remained consistent. Major stroke and procedure-related mortality were reported in 6 (2%) and 2 (0.7%) cases, respectively.ConclusionThese results demonstrate that SE has a consistently high effectiveness and favorable safety for the treatment of iAs.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献