A propensity score-matched comparative study of balloon guide catheters versus conventional guide catheters for concurrent mechanical thrombectomy with carotid stenting in tandem strokes: comparison of first pass effect, symptomatic intracranial hemorrhage, and 90-day functional outcomes

Author:

Baig Ammad AORCID,Waqas MuhammadORCID,Turner Ryan C,Kuo Cathleen C,Donnelly Brianna M,Lai Pui Man Rosalind,Raygor Kunal P,Bouslama Mehdi,Lim JaimsORCID,Neumaier BS Jenna,Cappuzzo Justin M,Davies Jason MORCID,Snyder Kenneth V,Siddiqui Adnan HORCID,Levy Elad IORCID

Abstract

BackgroundExtensive clot burden in tandem strokes accounts for poor mechanical thrombectomy (MT) outcomes. Several studies have shown the benefit of balloon guide catheters (BGCs) in MT and carotid artery stenting.ObjectiveIn view of this potential benefit, to investigate the safety and effectiveness of proximal flow arrest using a BGC during concurrent MT and carotid revascularization for tandem stroke treatment in a comparative, propensity score-matched (PSM) study.MethodsPatients with a tandem stroke identified from our endovascular database were dichotomized into groups treated with BGCs versus conventional guide catheters. One-to-one PSM adjustment for baseline demographics and treatment selection bias using nearest-neighbor matching was performed. Patient demographics, presentation characteristics, and procedural details were recorded. Outcomes assessed were final modified Thrombolysis in Cerebral Infarction (mTICI) grade, periprocedural symptomatic intracranial hemorrhage (sICH) rate, in-hospital mortality, and 90-day modified Rankin Scale (mRS) score. Mann-Whitney U test and multivariate logistic regression were performed to compare procedural parameters and clinical outcomes.ResultsConcurrent carotid revascularization (stenting with/without angioplasty) and MT was performed in 125 cases (BGC: 85; no BGC: 40). After PSM (40 patients/group), the BGC group had a significantly shorter procedure duration (77.9 vs 61.5 min; OR=0.996; P=0.006), lower discharge National Institutes of Health Stroke Scale score (8.0 vs 11.0; OR=0.987; P=0.042), and higher odds of 90-day mRS 0–2 score (52.3% vs 27.5%; OR=0.34; P=0.040). On multivariate regression, the BGC group had a significantly higher first pass effect rate (mTICI 2b or 3)(OR=1.115, 95% CI 1.015 to 1.432; P=0.013) and lower periprocedural sICH rate (OR=0.615, 95% CI 0.406 to 0.932; P=0.025). No difference in in-hospital mortality was observed (OR=1.591, 95% CI 0.976 to 2.593; P=0.067).ConclusionBGCs used for concurrent MT–carotid revascularization with flow arrest were safe and resulted in superior clinical and angiographic outcomes in patients with a tandem stroke.

Publisher

BMJ

Subject

Neurology (clinical),General Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3