Effects of Electroacupuncture at Bl33 on Detrusor Smooth Muscle Activity in a Rat Model of Urinary Retention

Author:

Liu Xiaoxu12,Liu Kun3,Zhi Mujun4,Mo Qian5,Gao Xinyan3,Liu Zhishun1

Affiliation:

1. Department of Acupuncture, Guang'anmen Hospital, China Academy of Chinese Medical Sciences, Beijing, China

2. Beijing University of Chinese Medicine, Beijing, China

3. Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Sciences, Beijing, China

4. Changchun University of Chinese Medicine, Changchun, Jilin, China

5. Guiyang University of Chinese Medicine, Guiyang, Guizhou, China

Abstract

Background Detrusor smooth muscle (DSM) underactivity may lead to urinary retention (UR). Electroacupuncture (EA) at BL33 may be effective in improving DSM contractions. Objectives This study aimed to investigate: (1) the effect of EA at BL33; and (2) the effect of different manipulation methods at BL33 on the modulation of DSM contractions in UR rats. Methods 30 male Sprague-Dawley rats were anaesthetised with urethane and modelled by urethral outlet obstruction. First, 2 Hz EA at BL33, SP6 and LI4 wasrandomly applied to the UR rats for 5 min to observe the immediate effects (n=10); second, manual acupuncture (MA) (n=10) and 100 Hz EA (n=10) were applied with the same programme. DSM electromyography (EMG) and cystometrogram data were evaluated. Results (1) 2 Hz EA at BL33 and SP6 significantly increased DSM discharging frequency (0.80±0.10 Hz, P<0.001, and 0.22±0.14 Hz, P=0.038), shortened micturation intervals (65.67±20.65 s, P=0.008, and 35.62±15.84 s, P=0.042), prolonged the duration of voiding (2.13±0.61 s, P=0.005, and 0.47±0.16 s, P=0.015), and reduced residual pressure (−0.91±0.31 mmHg, P=0.019, and −0.66±0.27 mmHg, P=0.046). EA at LI4 was not associated with any functional effects (P>0.05). Compared with SP6, EA at BL33 had greater positive effects on DSM discharging frequency, duration of discharging, and duration of voiding (all P<0.05). (2) No statistically significant differences were shown between MA, 2 Hz EA and 100 Hz EA interventions when stimulating at BL33, SP6 or LI4. Conclusions EA at BL33 improved DSM contractions to a greater degree than EA at SP6 or LI4. There were no differences in effect when stimulating using 2 Hz EA, 100 Hz EA and MA.

Funder

This study was supported by the National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Neurology (clinical),Complementary and alternative medicine,General Medicine