Safety Recommendations for Moxa Use Based on the Concentration of Noxious Substances Produced during Commercial Indirect Moxibustion

Author:

Kwon O Sang1,Cho Seong Jin1,Choi Kwang-Ho1,Yeon Sun Hee1,Kang Suk-Yun1,Kim Jae-hyo2,Ahn Seong-Hun2,Ryu Yeonhee1

Affiliation:

1. KM Fundamental Research Division, Korean Institute of Oriental Medicine, Daejeon, Korea

2. Department of Meridian & Acupuncture Point, College of Korean Medicine, Wonkwang University, Iksan, Korea

Abstract

Background Moxibustion therapy has been used historically for thousands of years and there are many clinical trials supporting its efficacy and effectiveness for various conditions. Moxa smoke has been a major reason for avoiding moxibustion due to its smell and potential risks to the human body. Methods 10 units of commercial indirect moxa (CIM) from six manufacturers (A–F) were burnt in a 2.5×2.5×2.5 m chamber without ventilation, and concentrations of carbon oxides (CO and CO2), nitrogen oxides (NOx), and volatile organic compounds (VOCs) from the indoor air samples were measured. Results For brands A, B, C, D, E, and F, respectively, relative to baseline values, we observed an increase in CO (from 0.002 to 0.007, 0.006, 0.005, 0.006, 0.005, and 0.006 parts per billion (ppb)), NOx (from 0.009 to 0.051, 0.025, 0.015, 0.050, 0.019, and 0.020 ppb), and total VOCs (TVOC; from 48.06 to 288.83, 227.93, 140.82, 223.22, 260.15, and 161.35 μg/m3), while the concentration of CO2 was not elevated. Each CIM brand demonstrated different VOC emission characteristics, which could be divided into three groups. On average, we estimated that 20 units of CIM or 2.41 g moxa floss would need to be combusted in order to exceed the safe levels set by Korean environmental law. This limit is likely to be greater in the case of a larger room or use of ventilation. Conclusions Despite increased CO/NOx/VOC concentrations, overall levels remained within safe limits. These findings may help clinicians to maintain safe moxibustion treatment conditions to help keep both patients and clinicians safe from the pollutants generated by moxa combustion.

Funder

Korea Evaluation Institute of Industrial Technology

Korea Institute of Oriental Medicine

Publisher

SAGE Publications

Subject

Clinical Neurology,Complementary and alternative medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370