IntroductionAdministering supplemental oxygen is a standard of care for trauma casualties to minimise the deleterious effects of hypoxaemia. Forward deployment of oxygen using pressurised cylinders is challenging, for example, logistics (weight and finite resource) and environmental risk (fire and explosion). Oxygen concentrators may overcome these challenges. Although previous studies successfully demonstrated fractional inspired oxygen (FiO2) >0.8 using oxygen concentrators and ventilators, the systems did not fulfil the size, weight and power requirements of agile military medical units. This study evaluated whether a modular system of commercially available clinical devices could supply high FiO2to either ventilated or spontaneously breathing casualties.MethodsAs a proof of principle, we configured an Inogen One G5 oxygen concentrator, Ventway Sparrow ventilator and Wenoll rebreather system to ventilate a simulated lung (tidal volume 500 mL). Casualty oxygen consumption (gas withdrawal inspiratory limb) and carbon dioxide (CO2) production (CO2added expiratory limb) were simulated (respiratory quotient of 0.7–0.8). Three circuit configurations were evaluated: open (supplementary oxygen introduced into air inlet of ventilator); semiclosed (ventilator replaces rebreather bag of Wenoll, oxygen connected to either ventilator or Wenoll); and semiclosed with reservoir tubing (addition of ‘deadspace’ tube between ventilator patient circuit and Wenoll). Data presented as mean and 95% reference range.ResultsThere were modest increases in FiO2with increasing Inogen settings in ‘open’ configuration 0.23 (0.23–0.24) and 0.30 (0.28–0.32) (Inogen output 420 and 1260 mL/min, respectively). With the ‘semiclosed’ configuration and oxygen added directly into rebreather circuit, FiO2increased to 0.36 (0.36–0.37). The addition of the ‘reservoir tubing’ elevated FiO2to 0.78 (0.71–0.85). FiO2remained stable over a 4-hour evaluation period. Fractional inspired carbon dioxide CO2increased over time, reaching 0.005 after 170 (157–182) min.ConclusionCombining existing lightweight devices can deliver high (>0.8) FiO2and offers a potential solution for the forward deployment of oxygen without needing pressurised cylinders.

Funder

Ministry of Defence

Publisher

BMJ

Reference26 articles.

1. American_College_of_Surgeons_Committee_on_Trauma . Advanced trauma life support: student course manual. 10th edn. Chicago, IL: American College of Surgeons, 2018.

2. Use of supplemental oxygen in emergency patients: a systematic review and recommendations for military clinical practice

3. Oxygen therapy in acute resuscitation;Frei;Curr Opin Crit Care,2018

4. North Atlantic Treaty Organisation . Medical management of CBRN casualties. NATO Standardisation Office (NSO), 2018.

5. Independent early predictors of mortality in polytrauma patients: a prospective, observational, longitudinal study;da Costa;Clinics (Sao Paulo),2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3