Time series evaluation of improvement interventions to reduce alarm notifications in a paediatric hospital

Author:

Pater Colleen MORCID,Sosa Tina K,Boyer Jacquelyn,Cable Rhonda,Egan Melinda,Knilans Timothy K,Schondelmeyer Amanda C,Schuler Christine L,Madsen Nicolas L

Abstract

Background10The Joint Commission identified inpatient alarm reduction as an opportunity to improve patient safety; enhance patient, family and nursing satisfaction; and optimise workflow. We used quality improvement (QI) methods to safely decrease non-actionable alarm notifications to bedside providers.MethodsIn a paediatric tertiary care centre, we convened a multidisciplinary team to address alarm notifications in our acute care cardiology unit. Alarm notification was defined as any alert to bedside providers for each patient-triggered monitor alarm. Our aim was to decrease alarm notifications per monitored bed per day by 60%. Plan-Do-Study-Act testing cycles included updating notification technology, establishing alarm logic and modifying bedside workflow processes, including silencing the volume on all bedside monitors. Our secondary outcome measure was nursing satisfaction. Balancing safety measures included floor to intensive care unit transfers and patient acuity level.ResultsAt baseline, there was an average of 71 initial alarm notifications per monitored bed per day. Over a 3.5-year improvement period (2014–2017), the rate decreased by 68% to 22 initial alarm notifications per monitored bed per day. The proportion of initial to total alarm notifications remained stable, decreasing slightly from 51% to 40%. There was a significant improvement in subjective nursing satisfaction. At baseline, 32% of nurses agreed they were able to respond to alarms appropriately and quickly. Following interventions, agreement increased to 76% (p<0.001). We sustained these improvements over a year without a change in monitored balancing measures.ConclusionWe successfully reduced alarm notifications while preserving patient safety over a 4-year period in a complex paediatric patient population using technological advances and QI methodology. Continued efforts are needed to further optimise monitor use across paediatric hospital units.

Publisher

BMJ

Subject

Health Policy

Reference31 articles.

1. Monitor Alarm Fatigue: An Integrative Review

2. Alarm-notification problem spotlighted in Boston globe is all too common. Health Devices 2010;39:139.

3. Alarm fatigue sets off bells;McKinney;Mod Healthc,2010

4. Clinical alarm hazards: a “top ten” health technology safety concern

5. The Joint Commission . The Joint Commission sentinel event alert: medical device alarm safety in hospitals. Jt Commision 2013:1–3 https://www.jointcommission.org/assets/1/6/SEA_50_alarms_4_26_16.pdf