System approach to prevent lost studies and improve radiology report turnaround time

Author:

Schick Jacob,Petscavage-Thomas Jonelle MORCID

Abstract

PurposeOn our picture archiving and communication system worklist, there was no way to differentiate body imaging (BI) from musculoskeletal (MSK) MR pelvis examinations. They were listed on only the BI worklist. This resulted in ‘lost’ MSK MR pelvis studies with high report turnaround time (TAT). Some exams had preliminary reports with substantiative changes made days later when found. The goals of this project were to create a solution to prevent ‘lost’ exams and improve TAT.MethodsA report of 3 months of MR pelvis studies was reviewed to determine time to first view by MSK radiologists, time of completion, time of preliminary report and time of final signature. Mean TAT was calculated and exams with delays in reporting resident misinterpretation recorded.An MSK reserve flag was created for the BI radiologists to use when they found an MSK study on their worklist. The flag moved them onto the MSK reserve worklist. A second intervention included technologists placing the reserve on examination completion. After this, another 3 months of data was analysed.ResultsThere was a significant improvement (p=0.0018) in time to view by MSK from preintervention mean of 1125 min (n=107) to postintervention mean of 526 min (n=127). There was also a significant improvement (p=0.0033) in time to view inpatient and Emergency department cases from 927 min to 357 min. Time from study completion to final signature also improved from a mean of 1764 min to 838 min, though not statistically significant (p=0.08). There were five cases of delay in reporting resident misinterpretation preintervention and none postintervention.ConclusionOur intervention shows the importance of modifying human and informatics factors to solve a patient safety issue.Introduction

Publisher

BMJ

Subject

Public Health, Environmental and Occupational Health,Health Policy,Leadership and Management

Reference13 articles.

1. Quality metrics currently used in academic radiology departments: results of the QUALMET survey;Walker;Br J Radiol,2017

2. Practice Policy and Quality Initiatives: Decreasing Variability in Turnaround Time for Radiographic Studies from the Emergency Department

3. Communicating radiology results

4. Ref2: joint Commission. National patient safety goals, 2021. Available: https://www.jointcommission.org/-/media/tjc/documents/standards/national-patient-safety-goals/2021/npsg_chapter_hap_jan2021.pdf

5. Standards for Business Analytics and Departmental Workflow

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3