High precision but systematic offset in a standing bioelectrical impedance analysis (BIA) compared with dual-energy X-ray absorptiometry (DXA)

Author:

Potter Adam WORCID,Nindl Lyndsey J,Soto Lara D,Pazmino Angie,Looney David P,Tharion William J,Robinson-Espinosa Jasmine A,Friedl Karl E

Abstract

Bioelectrical impedance analysis (BIA) provides a practical method of body composition estimation for field research and weight management programmes, with devices and algorithms that have improved in recent years. We compared suitability of a commercial BIA system that uses multi-frequency-based proprietary algorithms (InBody 770, Cerritos, California, USA) and a laboratory-based validated single-frequency system (Quantum IV, RJL Systems, Clinton Township, Michigan, USA) with dual-energy X-ray absorptiometry (DXA) (iDXA, GE Lunar, Madison, Wisconsin, USA). Volunteers included fit non-obese active duty US Marines (480 men; 315 women), assessed by DXA and the two BIA systems. Both RJL and InBody BIA devices predicted DXA-based fat-free mass (FFM) (mean absolute error (MAE) 2.8 and 3.1 kg, respectively) and per cent body fat (%BF) (MAE 3.4% and 3.9%, respectively), with higher correlations from the InBody device (r2=0.96 (%BF) and 0.84 (FFM)) versus the RJL (r2=0.92 (%BF) and 0.72 (FFM)). InBody overpredicted FFM (bias +2.7, MAE 3.1 kg) and underpredicted %BF (bias −3.4 and MAE 3.9%) versus the RJL. A 3% correction factor applied to the InBody device results provided values very close to the DXA measurements. These findings support the application of modern BIA systems to body composition goals of maximum %BF and minimum lean body mass for both men and women.

Funder

US Army Military Operational Medicine Research Program

Publisher

BMJ

Subject

Nutrition and Dietetics,Medicine (miscellaneous),Health (social science)

Reference47 articles.

1. [Bioelectric properties of tissue. Impedance measurement in clinical medicine. Significance of curves obtained];Thomasset;Lyon Med,1962

2. Nyboer J . Electrical impedance plethysmography. In: Thomas CC , ed. Springfield, ill, 1959.

3. Correlation of whole-body impedance with total body water volume;Hoffer;J Appl Physiol,1969

4. Moore FD . The body cell mass and its supporting environment. London: W.B. Saunders, 1963.

5. University of Alaska high latitude study, and the MT. McKinley project, 1981-1983;Mills;Alaska Med,1983

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献