Accuracy of glycosuria, random blood glucose and risk factors as selective screening tools for gestational diabetes mellitus in comparison with universal diagnosing

Author:

Agbozo FaithORCID,Abubakari Abdulai,Narh Clement,Jahn Albrecht

Abstract

ObjectiveDespite the short-term and long-term health implications of gestational diabetes mellitus (GDM), opinions are divided on selective vis-à-vis universal screening. We validated the accuracy of screening tests for GDM.Research design and methodsPregnant women (n=491) were recruited to this prospective, blind comparison with a gold standard study. We did selective screening between 13 and 20 weeks using reagent-strip glycosuria, random capillary blood glucose (RBG) and the presence of ≥1 risk factor(s). Between 20 and 34 weeks, we did universal screening following the ‘one-step’ approach using glycated hemoglobin (HbA1c), fasting venous plasma glucose (FPG), and the 1-hour and the ‘gold standard’ 2-hour oral glucose tolerance test (OGTT). Tests accuracy was estimated following the WHO and the National Institute for Health and Care Excellence (NICE) diagnostic criteria. Overall test performance was determined from the area under the receiver operating characteristic curve (AUC).ResultsGDM prevalence per 2-hour OGTT was 9.0% for the WHO criteria and 14.3% for the NICE criteria. Selective screening using glycosuria, RBG and risk factors missed 97.4%, 87.2% and 45.7% of cases, respectively. FPG threshold ≥5.1 mmol/L had the highest clinically relevant sensitivity (68%) and specificity (81%), but FPG threshold ≥5.6 mmol/L had higher positive predictive value. Although sensitivity of 1-hour OGTT was 39.5%, it had the highest accuracy and diagnostic OR. Regarding test performance, 1-hour OGTT and FPG were very good (AUC>0.8), RBG was poor (AUC≈0.60), whereas HbA1c was invaluable (AUC<0.5).ConclusionsSelective screening using glycosuria and random blood glucose is unnecessary due to its low sensitivity. Fasting glucose ≥5.1 mmol/L could be applicable for screening at the population level. Where 2-hour OGTT is not available, FPG ≥5.6 mmol/L, complemented by the presence of risk factors, could be useful in making therapeutic decision.

Publisher

BMJ

Subject

Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3