Comparison of safety and usability between peristaltic and pneumatic large-volume intravenous smart pumps during actual clinical use

Author:

Penoyer Daleen,Giuliano Karen,Middleton Aurea

Abstract

ObjectiveTo describe and compare safety and usability between a peristaltic large-volume intravenous smart pump (IVSP) and a novel pneumatic large-volume IVSP during clinical use.MethodsA prospective, comparative study was conducted in a large, tertiary hospital in the southeastern USA. Safety and usability were measured by observation during medication administration (medication administration error, interruptions, programming time), dose error reduction system (DERS) compliance, end-user surveys and compliance with manufacturer setup requirements. Study implementation began on a small pilot unit for 1 month, followed by data collection on the study unit over 2 months.ResultsFor the observed medication administrations (N=158): 79 peristaltic (36 primary; 43 secondary) and 79 pneumatic (42 primary; 37 secondary), use of the peristaltic IVSP was associated with significantly (p<0.05) higher medication administration errors and programming time (11.9 s) and a significantly higher number of interruptions during programming.DERS compliance was significantly less (p<0.001) with the peristaltic (75.9%) as compared with the pneumatic IVSP (99.8%). Programming workload (National Aeronautics and Space Administration Task Load Index) was significantly (p=0.004) higher with peristaltic versus pneumatic IVSP, and the usability (System Usability Scale) was significantly (p=0.007) lower with peristaltic versus pneumatic IVSP. There was a 0% compliance with peristaltic secondary setup requirements in 43 observed infusions.ConclusionsThough nurses had a high level of experience with the peristaltic IVSP, results of this study support that the pneumatic IVSP was easier to use and associated with fewer errors and deviations from safe practices as compared with the peristaltic IVSP.

Funder

Ivenix, Inc.

Publisher

BMJ

Subject

General Medicine

Reference30 articles.

1. Insights from the sharp end of intravenous medication errors: implications for infusion pump technology

2. Are smart pumps smart enough?;Giuliano;Nursing,2017

3. Ohashi K , Dykes PC , McIntosh K . Evaluation of intravenous medication errors with smart infusion pumps in an academic medical center. American Medical Informatics Association, 2013: 10.

4. The Use of Smart Pumps for Preventing Medication Errors

5. Smart infusion technology: a minimum safety standard for intensive care?

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3