Mandibular advancement device versus CPAP in lowering 24-hour blood pressure in patients with obstructive sleep apnoea and hypertension: the CRESCENT trial protocol

Author:

Ou Yi-Hui,Colpani Juliana Tereza,Chan Siew-Pang,Loke Weiqiang,Cheong Crystal S,Kong William,Chin Calvin W,Kojodjojo PipinORCID,Wong Philip,Cistulli Peter,Lee Chi-HangORCID

Abstract

IntroductionAlthough treatment of obstructive sleep apnoea (OSA) using continuous positive airway pressure (CPAP) reduces blood pressure (BP), adherence to CPAP is often suboptimal. A mandibular advancement device (MAD) is a guideline-endorsed alternative therapy for OSA. Still, there is limited evidence on the relative efficacy between MAD and CPAP on BP reduction. We evaluate whether treatment of moderate-to-severe OSA using MAD can improve BP and other health-related outcomes compared with CPAP.Methods and analysisThis is a randomised, controlled, non-inferiority trial conducted. We will recruit 220 Asians with a history of hypertension and high cardiovascular risk for an overnight polysomnography screening. Those with moderate-to-severe OSA (apnoea–hypopnoea index ≥15 events/hour) will be randomised to treatment with either MAD or CPAP in a 1:1 ratio. Stratified by age (60 vs <60 years old), body mass index (25 vs <25 kg/m2) and apnoea–hypopnoea index (30 vs <30 events/hour), an adaptive randomisation scheme with permuted blocks constructed in real-time is implemented to restrict imbalance. The overall study duration is 12 months. The primary endpoint is the 24-hour mean arterial BP difference between baseline and 6-month follow-up. The secondary endpoints include other measures of ambulatory BP monitoring, arrhythmia based on a 4-day electrocardiographic monitoring, biomarker and proteomic analysis, cardiovascular magnetic resonance-derived myocardial fibrosis and remodelling and quality-of-life questionnaires. Recruitment began in October 2019 and ended in December 2022. Comparison between MAD and CPAP will be performed using covariance (ANCOVA) analysis of the changes in 24-hour mean arterial BP while adjusting for the baseline 24-hour mean arterial BP. We will compare the 95% CIs around the treatment difference point estimate with the prespecified non-inferiority margin (1.5 mm Hg). If the upper limit of the 95% CI is <1.5 mm Hg and crosses 0, non-inferiority of the MAD relative to CPAP will be established.Ethics and disseminationThe Domain Specific Review Board-C, National Healthcare Group under approved the study protocol (NHG DSRB Ref: 2019/00359, approved on 28 August 2019). Study findings will be disseminated to various local, national, and international audiences through abstract presentations and publication in peer-reviewed journals.Trial registration numberNCT04119999.

Funder

National Medical Research Council

National University of Singapore

Publisher

BMJ

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3