Differences in patient characteristics, clinical practice and outcomes of cardiac implantable electric device therapy between Japan and the USA: a cross-sectional study using data from nationally representative administrative databases

Author:

Tonegawa-Kuji ReinaORCID,Inoue Yuko Y,Nakai Michikazu,Kanaoka KoshiroORCID,Sumita Yoko,Miyazaki Yuichiro,Wakamiya Akinori,Shimamoto KeikoORCID,Ueda Nobuhiko,Nakajima Kenzaburo,Wada Mitsuru,Kamakura TsukasaORCID,Yamagata Kenichiro,Ishibashi Kohei,Miyamoto Koji,Nagase Satoshi,Aiba TakeshiORCID,Miyamoto Yoshihiro,Iwanaga Yoshitaka,Kusano KengoORCID

Abstract

ObjectivesTo identify differences in patient characteristics, clinical practice and outcomes of cardiac implantable electronic device (CIED) therapy between Japan and the USA.DesignA cross-sectional study.SettingNationally representative administrative databases from Japan and the USA containing hospitalisations with first-time implantations of pacemakers, implantable cardioverter-defibrillators (ICD) and cardiac-resynchronisation therapy with or without defibrillators (CRTP/CRTD).ParticipantsPatients hospitalised with first-time implantations of CIEDs.Outcome measuresIn-hospital mortality, in-hospital complication and 30-day readmission rates.ResultsOverall, 107 339 (median age 78 (71–84), 48 415 women) and 295 584 (age 76 (67–83), 127 349 women) records with CIED implantations were included from Japan and the USA, respectively. Proportion of women in defibrillator recipients was lower in Japan than in the USA (ICD, 21% vs 28%, p<0.001; CRTD, 24% vs 29%, p<0.001). Length of stay after CIED implantation was longer in Japan than in the USA for all device types (conventional pacemaker, 8(7–11) vs 1 (1–3) days, p<0.001; leadless pacemaker, 5 (3–9) vs 2 (1–5) days, p<0.001; ICD, 8 (7–11) vs 1 (1–3) days, p<0.001, CRTP, 9 (7–13) vs 2 (1–4) days, p<0.001; CRTD, 9 (8–14) vs 2 (1–4) days, p<0.001). In-hospital mortality after CIED implantation was similar between Japan and the USA ((OR) (95% CI), conventional pacemaker 0.58 (0.83 to 1.004); ICD 0.77 (0.57 to 1.03); CRTP 0.85 (0.51 to 1.44); CRTD 1.11 (0.81 to 1.51)), except that after leadless pacemaker implantation in Japan was lower than that in the USA (0.32 (0.23 to 0.43)). 30-day readmission rates were lower in Japan than in the USA for all device types (conventional pacemaker 0.55 (0.53 to 0.57); leadless pacemaker 0.50 (0.43 to 0.58); ICD 0.54 (0.49 to 0.58); CRTP 0.51 (0.42 to 0.62); CRTD 0.57 (0.51 to 0.64)).ConclusionsInternational variations in patient characteristics, practice and outcomes were observed. In-hospital mortality after CIED implantation was similar between Japan and the USA, except in cases of leadless pacemaker recipients.

Funder

Japan Society for the Promotion of Science

National Cerebral and Cardiovascular Center

EP Cruise Inc.

Publisher

BMJ

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3