Abstract
IntroductionThe measurement of fractional exhaled nitric oxide (FeNO) is promising for diagnosing asthma and might substitute for bronchial provocation (BP) tests. To evaluate the diagnostic accuracy of FeNO within a confirmatory study, the following hypotheses will be tested: (1) A FeNO cut-off >50 ppb (parts per billion) is suitable for diagnosing asthma (sensitivity 35%, specificity 95%); (2) If the clinical symptoms ‘allergic rhinitis’ and ‘wheezing’ are present, asthma can be diagnosed at FeNO >33 ppb with a positive predictive value (PPV) >70% and (3) A FeNO >33 ppb can predict responsiveness to inhaled corticosteroid (ICS) with a PPV >70%.Methods and analysisA prospective diagnostic study will be conducted in three practices of pneumologists in Germany. 300 patients suspected of suffering from asthma will be included. As an index test, patients perform FeNO measurement with the device NIOX VERO. As reference a test, patients are examined with whole bodyplethysmography and BP, if necessary. After 3 months, patients with an asthma diagnosis will be examined again to verify the diagnosis and evaluate ICS responsiveness. Patients who did not receive an asthma diagnosis at the initial examination will be phoned after 3 months and asked about persistent respiratory symptoms to exclude false negative findings. As a primary target, sensitivity and specificity of FeNO >50 ppb will be determined. As a secondary target the PPV for asthma at FeNO >33 ppb, when the symptoms ‘allergic rhinitis’ and ‘wheezing’ are present, will be calculated. Regarding ICS responsiveness, the PPV of FeNO >33 ppb will be determined.Ethics and disseminationThe study was approved by the Ethical Committee of the Technical University of Munich (Reference number 122/20 S). The major results will be published in peer-reviewed academic journals and disseminated through conferences.Trial registration numberDRKS00021125.
Reference34 articles.
1. Bundesärztekammer (BÄK), Kassenärztliche Bundesvereinigung (KBV), Arbeitsgemeinschaft Der Wissenschaftli-chen Medizinischen Fachgesellschaften (AWMF) . Nationale VersorgungsLeitlinie asthma – Langfassung, 4. Auflage. Konsultationsfassung., 2020. Available: www.asthma.versorgungsleitlinien.de [Accessed 22 Jun 2020].
2. Global Initiative for Asthma . Global strategy for asthma management and prevention, 2020. Available: www.ginasthma.org
3. Peak flow variability in the SAPALDIA study and its validity in screening for asthma-related conditions. The SPALDIA team;Künzli;Am J Respir Crit Care Med,1999
4. Diagnostischer Wert der Peak-Flow-Variabilität bei Verdacht auf Asthma bronchiale in der Hausarztpraxis
5. FENO measurement and sputum analysis for diagnosing asthma in clinical practice
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献