Mini-sternotomy versus conventional sternotomy for aortic valve replacement: a randomised controlled trial

Author:

Hancock Helen CORCID,Maier Rebecca HORCID,Kasim Adetayo,Mason James,Murphy Gavin,Goodwin Andrew,Owens W AndrewORCID,Akowuah EnochORCID

Abstract

ObjectiveTo compare clinical and health economic outcomes after manubrium-limited mini-sternotomy (intervention) and conventional median sternotomy (usual care).DesignA single-blind, randomised controlled trial.SettingSingle centre UK National Health Service tertiary hospital.ParticipantsAdult patients undergoing aortic valve replacement (AVR) surgery.InterventionsIntervention was manubrium-limited mini-sternotomy performed using a 5–7 cm midline incision. Usual care was median sternotomy performed using a midline incision from the sternal notch to the xiphisternum.Primary and secondary outcome measuresThe primary outcome was the proportion of patients who received a red cell transfusion postoperatively and within 7 days of index surgery. Secondary outcomes included proportion of patients receiving a non-red cell blood component transfusion and number of units transfused within 7 days and during index hospital stay, quality of life and cost-effectiveness analyses.Results270 patients were randomised, received surgery and contributed to the intention to treat analysis. No difference between mini and conventional sternotomy in red-cell transfusion within 7 days was found; 23/135 patients in each arm received a transfusion, OR 1.0 (95% CI 0.5 to 2.0) and risk difference 0.0 (95% CI −0.1 to 0.1). Mini-sternotomy reduced chest drain losses (mean 181.6 mL (SD 138.7) vs conventional, mean 306·9 mL (SD 348.6)); this did not reduce red-cell transfusions. Mean valve size and postoperative valve function were comparable between mini-sternotomy and conventional groups; 23 mm vs 24 mm and 6/134 moderate or severe aortic regurgitation vs 3/130, respectively. Mini-sternotomy resulted in longer bypass (82.7 min (SD 23.5) vs 59.6 min (SD 15.1)) and cross-clamp times (64.1 min (SD 17.1) vs 46·3 min (SD 10.7)). Conventional sternotomy was more cost-effective with only a 5.8% probability of mini-sternotomy being cost-effective at a willingness to pay of £20 000/QALY (Quality Adjusted Life Years).ConclusionsAVR via mini-sternotomy did not reduce red blood cell transfusion within 7 days following surgery when compared with conventional sternotomy.Trial registration numberISRCTN29567910; Results.

Funder

National Institute for Health Research

Publisher

BMJ

Subject

General Medicine

Reference28 articles.

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3