Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study

Author:

Dalén MagnusORCID,Persson Michael,Glaser NatalieORCID,Sartipy UlrikORCID

Abstract

ObjectiveBioprosthetic aortic valves with an extended subannular component, such as transcatheter valves, exert increased compression on the cardiac conduction system and increase the risk for permanent pacemaker implantation. It is unknown if the On-X mechanical prosthetic valve, which has an elongated subannular valve housing, increases the risk of permanent pacemaker implantation following aortic valve replacement.DesignObservational nationwide cohort study.SettingSwedish population-based study.ParticipantsAll patients aged 18–65 years who underwent primary mechanical aortic valve replacement in Sweden between 2005 and 2018. We used the Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies register and other Swedish national health-data registers.ExposurePatients implanted with an On-X valve versus patients implanted with other bileaflet mechanical valves.Primary and secondary outcome measuresPrimary outcome measure was permanent pacemaker implantation within 30 days of surgery.ResultsA total of 2602 patients were included, and 581 patients received an On-X valve and 2021 patients received a St Jude Masters/Regent (n=945) or Carbomedics Reduced valve (n=1076). In the total study population, 115 (4.4%) permanent pacemaker implantations were performed within 30 days after aortic valve replacement. In the propensity score matched population, there was no significant difference in the rate of permanent pacemaker implantation in the On-X group compared with the control group: 3.6% (95% CI: 2.4% to 5.5%) vs 4.0% (95% CI: 2.7% to 5.9%), p=0.877.ConclusionsThe On-X prosthetic heart valve was associated with a similarly low risk for permanent pacemaker implantation after aortic valve replacement compared with other conventional bileaflet mechanical valves. The On-X elongated subannular valve housing does not interfere with the cardiac conduction system.

Funder

Swedish Society of Medicine

ALF

Åke Wiberg Foundation

Swedish Heart-Lung Foundation

Mr. Fredrik Lundberg

Capio Research Foundation

Publisher

BMJ

Subject

General Medicine

Reference30 articles.

1. Incidence and Risk Factors for Permanent Pacemaker Implantation Following Mitral or Aortic Valve Surgery

2. Need for permanent pacemaker after surgical aortic valve replacement reduces long-term survival;Mehaffey;Ann Thorac Surg,2018

3. Incidence, indications, risk factors, and survival of patients undergoing cardiac implantable electronic device implantation after open heart surgery;Wiggins;Europace,2017

4. Prevalence of and risk factors for permanent pacemaker implantation after aortic valve replacement;Levack;Ann Thorac Surg,2019

5. Conduction disturbances following surgical aortic valve replacement with a rapid-deployment bioprosthesis;Coti;J Thorac Cardiovasc Surg,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3