Standard automated perimetry using size III and size V stimuli in advanced stage glaucoma: an observational cross-sectional comparative study

Author:

Sood Devindra,Czanner Gabriela,Somerville Tobi,Sood Ishaana,Rowe Fiona JORCID

Abstract

ObjectivesIn this study, we sought to evaluate the extent of further visual field that could be assessed when using stimulus size V in standard automated perimetry compared with size III in advanced stage glaucoma and whether cut-off values could be determined for when to switch from size III to size V.DesignProspective cross-sectional study.SettingSingle-centre outpatient eye clinic in India (New Delhi).ParticipantsAdvanced stage glaucoma defined as stages 3–4.InterventionCentral static perimetry with Octopus 900 G programme (size III stimulus dynamic strategy) and low vision central programme (size V stimulus dynamic strategy).Primary and secondary outcome measuresVisual field assessment for right and left eyes with both sizes III and V were undertaken within one clinic visit.ResultsWe recruited 126 patients (170 eyes). Mean patient age at assessment was 55.86 years (SD 15.15). Means (SD) for size III versus size V, respectively, were 6.94 dB (5.58) and 12.98 dB (7.77) for mean sensitivity, 20.02 dB (5.67) and 19.22 dB (7.74) for mean deviation, 5.89 dB (2.29) and 7.69 dB (2.78) for standard loss variance and 3.32 min (1.07) and 6.40 min (1.43) for test duration. All except mean deviation were significantly different between size III and V tests.ConclusionUseful visual field information was obtained with size V stimuli which allowed continued monitoring of these patients that was not possible with size III. Increased test duration, standard loss variance and mean sensitivity were found with size V, as expected, given that more visual responses were obtained with the increased target size. A switch from size III to V may be considered when mean sensitivity reaches 10 dB and/or mean deviation reaches 18 dB.

Publisher

BMJ

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Correlation Between Visual Acuity and Foveal Threshold by Automated Perimetry With Size V Stimulus;Journal of Neuro-Ophthalmology;2023-12-19

2. Advanced glaucoma. Clinical practice guideline;Archivos de la Sociedad Española de Oftalmología (English Edition);2023-01

3. Glaucoma avanzado. Guía de práctica clínica;Archivos de la Sociedad Española de Oftalmología;2023-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3