Diagnostic accuracy of subjective dyspnoea in detecting hypoxaemia among outpatients with COVID-19: a retrospective cohort study

Author:

Berezin Linor,Zhabokritsky Alice,Andany Nisha,Chan Adrienne K,Estrada-Codecido Jose,Gershon Andrea,Lam Philip W,Leis Jerome A,MacPhee Scott,Mubareka Samira,Simor Andrew E,Daneman NickORCID

Abstract

ObjectivesThe majority of patients with mild-to-moderate COVID-19 can be managed using virtual care. Dyspnoea is challenging to assess remotely, and the accuracy of subjective dyspnoea measures in capturing hypoxaemia have not been formally evaluated for COVID-19. We explored the accuracy of subjective dyspnoea in diagnosing hypoxaemia in COVID-19 patients.MethodsThis is a retrospective cohort study of consecutive outpatients with COVID-19 who met criteria for home oxygen saturation monitoring at a university-affiliated acute care hospital in Toronto, Canada from 3 April 2020 to 13 September 2020. Dyspnoea measures were treated as diagnostic tests, and we determined their sensitivity (SN), specificity (SP), negative/positive predictive value (NPV/PPV) and positive/negative likelihood ratios (+LR/−LR) for detecting hypoxaemia. In the primary analysis, hypoxaemia was defined by oxygen saturation <95%; the diagnostic accuracy of subjective dyspnoea was also assessed across a range of oxygen saturation cutoffs from 92% to 97%.ResultsDuring the study period, 89/501 (17.8%) of patients met criteria for home oxygen saturation monitoring, and of these 17/89 (19.1%) were diagnosed with hypoxaemia. The presence/absence of dyspnoea had limited accuracy for diagnosing hypoxaemia, with SN 47% (95% CI 24% to 72%), SP 80% (95% CI 68% to 88%), NPV 86% (95% CI 75% to 93%), PPV 36% (95% CI 18% to 59%), +LR 2.4 (95% CI 1.2 to 4.7) and −LR 0.7 (95% CI 0.4 to 1.1). The SN of dyspnoea was 50% (95% CI 19% to 81%) when a cut-off of <92% was used to define hypoxaemia. A modified Medical Research Council dyspnoea score >1 (SP 98%, 95% CI 88% to 100%), Roth maximal count <12 (SP 100%, 95% CI 75% to 100%) and Roth counting time <8 s (SP 93%, 95% CI 66% to 100%) had high SP that could be used to rule in hypoxaemia, but displayed low SN (≤50%).ConclusionsSubjective dyspnoea measures have inadequate accuracy for ruling out hypoxaemia in high-risk patients with COVID-19. Safe home management of patients with COVID-19 should incorporate home oxygenation saturation monitoring.

Publisher

BMJ

Subject

General Medicine

Reference26 articles.

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3