Safety and efficacy of 2% chlorhexidine gluconate aqueous versus 2% chlorhexidine gluconate in 70% isopropyl alcohol for skin disinfection prior to percutaneous central venous catheter insertion in preterm neonates: the ARCTIC randomised-controlled feasibility trial protocol

Author:

Clarke PaulORCID,Craig Jean V,Wain John,Tremlett Catherine,Linsell Louise,Bowler Ursula,Juszczak Ed,Heath Paul T

Abstract

IntroductionCatheter-related sepsis is one of the most dangerous complications of neonatal intensive care and is associated with significant morbidity and mortality. Use of catheter-care ‘bundles’ has reduced the incidence of catheter-related sepsis, although individual components have not been well studied. Better evidence is needed to guide selection of the most appropriate antiseptic solution for skin disinfection in preterm neonates. This study will inform the feasibility and design of the first randomised controlled trial to examine the safety and efficacy of alcohol-based versus aqueous-based chlorhexidine antiseptic formulations for skin disinfection prior to percutaneous central venous catheterisation in preterm neonates. The antiseptics to be compared are 2% chlorhexidine gluconate (CHG) aqueous and 2% CHG in 70% isopropyl alcohol.Methods and analysisThe Antiseptic Randomised Controlled Trial for Insertion of Catheters (ARCTIC) is a two-centre randomised-controlled feasibility trial. At least 100 preterm infants born at <34 weeks’ gestation and due to undergo percutaneous insertion of a central venous catheter will be randomly allocated to receive prior skin disinfection with one of the two antiseptic solutions. Outcomes include: i) recruitment and retention rates; ii) completeness of data collection; iii) numbers of enrolled infants meeting case definitions for definite catheter-related sepsis, catheter-associated sepsis and catheter colonisation and iv) safety outcomes of skin morbidity scores recorded daily from catheter insertion until 48 hours post removal. The key feasibility metrics will be reported as proportions with 95% CIs. Estimated prevalence of catheter colonisation will allow calculation of sample size for the large-scale trial. The data will inform whether it will be feasible to progress to a large-scale trial.Ethics and disseminationARCTIC has been approved by the National Health Service Health Research Authority National Research Ethics Service Committee East of England (Cambridge South) (IRAS ID 163868), was adopted onto the National Institute of Health Research Clinical Research Network portfolio (CPMS ID 19899) and is registered with an International Standard Randomised Control Trials Number (ISRCTN: 82571474; Pre-results) and European Clinical Trials Database number 2015-000874-36. Dissemination plans include presentations at scientific conferences, scientific publications and sharing of the findings with parents via the support of Bliss baby charity.Trial registration numberISRCTN82571474; Pre-results.

Funder

NIHR Research for Patient Benefit

Publisher

BMJ

Subject

General Medicine

Reference22 articles.

1. Segmental percutaneous central venous line cultures for diagnosis of catheter-related sepsis

2. Skin colonisation at the catheter exit site is strongly associated with catheter colonisation and catheter-related sepsis;Ponnusamy;Acta Paediatr,2014

3. Devastating coagulase-negative staphylococcal septicaemia in an extremely low birth weight infant

4. Question 2: Does coagulase negative staphylococcal sepsis cause neurodevelopmental delay in preterm infants?

5. Department of Health (2007). Saving Lives: reducing infection, delivering clean and safe care. High Impact Intervention No 1. Central venous catheter care bundle. https://webarchive.nationalarchives.gov.uk/20100604210903/http://www.dh.gov.uk/en/Publicationsandstatistics/Publications/PublicationsPolicyAndGuidance/DH_078134

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3