Timing of device reimplantation and reinfection rates following cardiac implantable electronic device infection: a systematic review and meta-analysis

Author:

Chew DerekORCID,Somayaji Ranjani,Conly John,Exner Derek,Rennert-May Elissa

Abstract

ObjectivesInitial management of cardiac implantable electronic device (CIED) infection requires removal of the infected CIED system and treatment with systemic antibiotics. However, the optimal timing to device reimplantation is unknown. The aim of this study was to quantify the incidence of reinfection after initial management of CIED infection, and to assess the effect of timing to reimplantation on reinfection rates.DesignSystematic review and meta-analysis.InterventionsA systematic review and meta-analysis was performed of studies published up to February 2018. Inclusion criteria were: (a) documented CIED infection, (b) studies that reported the timing to device reimplantation and (c) studies that reported the proportion of participants with device reinfection. A meta-analysis of proportions using a random effects model was performed to estimate the pooled device reinfection rate.Primary and secondary outcome measuresThe primary outcome measure was the rate of CIED reinfection. The secondary outcome was all-cause mortality.ResultsOf the 280 screened studies, 8 met inclusion criteria with an average of 96 participants per study (range 15–220 participants). The pooled incidence rate of device reinfection was 0.45% (95% CI, 0.02% to 1.23%) per person year. A longer time to device reimplantation >72 hours was associated with a trend towards higher rates of reinfection (unadjusted incident rate ratio 4.8; 95% CI 0.9 to 24.3, p=0.06); however, the meta-regression analysis was unable to adjust for important clinical covariates. There did not appear to be a difference in reinfection rates when time to reimplantation was stratified at 1 week. Heterogeneity was moderate (I2=61%).ConclusionsThe incident rate of reinfection following initial management of CIED infection is not insignificant. Time to reimplantation may affect subsequent rates of device reinfection. Our findings are considered exploratory and significant heterogeneity limits interpretation.PROSERO registration numberCRD4201810960.

Publisher

BMJ

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3