Real-world outcomes comparison among adults with atrial fibrillation undergoing catheter ablation with a contact force porous tip catheter versus a second-generation cryoballoon catheter: a retrospective analysis of multihospital US database

Author:

Costea Alexandru,Goldstein Laura,Maccioni Sonia,Kalsekar Iftekhar,Khanna RahulORCID

Abstract

ObjectiveTo compare real-world clinical and economic outcomes among atrial fibrillation (AF) patients undergoing cardiac ablation with the contact force-sensing porous tip THERMOCOOL SMARTTOUCH SF (STSF) catheter versus the Arctic Front Advance Cryoballoon (AFA-CB) catheter.DesignRetrospective, observational cohort study.SettingPremier Healthcare Database (PHD), between 1 September 2016 and 30 June 2018.ParticipantsPatients with AF (≥18 years) were included if they had an index ablation procedure performed using the STSF catheter or AFA-CB catheter at a US hospital that consistently provided inpatient and outpatient data to PHD in the 12-month preindex period. Using 1:1 propensity score matching, patient groups were matched on study covariates.Primary and secondary outcome measuresCost, length of stay (LOS), readmissions, direct current cardioversion (DCCV) and reablation outcomes were compared between matched cohorts of STSF and AFA-CB patients.ResultsA total of 3015 patients with AF met the study criteria, of which 1720 had ablation using the STSF catheter and 1295 had ablation using the AFA-CB catheter. In the propensity-matched sample, patients receiving ablation with the STSF catheter had ~17% lower total costs (US$23 096 vs US$27 682, p≤0.0001) and ~27% lower supply costs (US$10 208 vs US$13 816, p≤0.0001) versus patients receiving ablation with the AFA-CB catheter. A significantly lower likelihood of 4-month to 6-month cardiovascular-related readmission (OR 0.460, 95% CI 0.220 to 0.959) was associated with the STSF catheter versus the AFA-CB catheter. No significant differences in LOS, room and board cost, 4-month to 6-month all-cause and AF-related readmissions, DCCV and reablation were observed among technologies. Sensitivity analysis restricting patient sample by provider ablation volume demonstrated similar results.ConclusionLower index ablation total and supply costs were observed among patients with AF undergoing cardiac catheter ablation using the STSF catheter versus the AFA-CB catheter.

Publisher

BMJ

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3