Automated multidimensional deep learning platform for referable diabetic retinopathy detection: a multicentre, retrospective study

Author:

Zhang Guihua,Lin Jian-Wei,Wang JiORCID,Ji Jie,Cen Ling-Ping,Chen WeiqiORCID,Xie Peiwen,Zheng Yi,Xiong Yongqun,Wu Hanfu,Li Dongjie,Ng Tsz KinORCID,Pang Chi Pui,Zhang MingzhiORCID

Abstract

ObjectiveTo develop and validate a real-world screening, guideline-based deep learning (DL) system for referable diabetic retinopathy (DR) detection.DesignThis is a multicentre platform development study based on retrospective, cross-sectional data sets. Images were labelled by two-level certificated graders as the ground truth. According to the UK DR screening guideline, a DL model based on colour retinal images with five-dimensional classifiers, namely image quality, retinopathy, maculopathy gradability, maculopathy and photocoagulation, was developed. Referable decisions were generated by integrating the output of all classifiers and reported at the image, eye and patient level. The performance of the DL was compared with DR experts.SettingDR screening programmes from three hospitals and the Lifeline Express Diabetic Retinopathy Screening Program in China.Participants83 465 images of 39 836 eyes from 21 716 patients were annotated, of which 53 211 images were used as the development set and 30 254 images were used as the external validation set, split based on centre and period.Main outcomesAccuracy, F1 score, sensitivity, specificity, area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC), Cohen’s unweighted κ and Gwet’s AC1 were calculated to evaluate the performance of the DL algorithm.ResultsIn the external validation set, the five classifiers achieved an accuracy of 0.915–0.980, F1 score of 0.682–0.966, sensitivity of 0.917–0.978, specificity of 0.907–0.981, AUROC of 0.9639–0.9944 and AUPRC of 0.7504–0.9949. Referable DR at three levels was detected with an accuracy of 0.918–0.967, F1 score of 0.822–0.918, sensitivity of 0.970–0.971, specificity of 0.905–0.967, AUROC of 0.9848–0.9931 and AUPRC of 0.9527–0.9760. With reference to the ground truth, the DL system showed comparable performance (Cohen’s κ: 0.86–0.93; Gwet’s AC1: 0.89–0.94) with three DR experts (Cohen’s κ: 0.89–0.96; Gwet’s AC1: 0.91–0.97) in detecting referable lesions.ConclusionsThe automatic DL system for detection of referable DR based on the UK guideline could achieve high accuracy in multidimensional classifications. It is suitable for large-scale, real-world DR screening.

Funder

Medical College Of Shantou University

Shantou Science and Technology Bureau

Publisher

BMJ

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3