Design and validation of a new Healthcare Systems Usability Scale (HSUS) for clinical decision support systems: a mixed-methods approach

Author:

Ghorayeb AbirORCID,Darbyshire Julie LORCID,Wronikowska Marta WORCID,Watkinson Peter JORCID

Abstract

ObjectiveTo develop and validate a questionnaire to assess the usability of clinical decision support systems (CDSS) and to assist in the early identification of usability issues that may impact patient safety and quality of care.DesignMixed research methods were used to develop and validate the questionnaire. The qualitative study involved scale item development, content and face validity. Pilot testing established construct validity using factor analysis and facilitated estimates for reliability and internal consistency using the Cronbach’s alpha coefficient.SettingTwo hospitals within a single National Health Service Trust.ParticipantsWe recruited a panel of 7 experts in usability and questionnaire writing for health purposes to test content validity; 10 participants to assess face validity and 78 participants for the pilot testing. To be eligible for this last phase, participants needed to be health professionals with at least 3 months experience using the local hospital electronic patient record system.ResultsFeedback from the face and content validity phases contributed to the development and improvement of scale items. The final Healthcare Systems Usability Scale (HSUS) proved quick to complete, easy to understand and was mostly worded by potential users. Exploratory analysis revealed four factors related to patient safety, task execution, alerts or recommendations accuracy, the effects of the system on workflow and ease of system use. These separate into four subscales: patient safety and decision effectiveness (seven items), workflow integration (six items), work effectiveness (five items) and user control (four items). These factors affect the quality of care and clinician’s ability to make informed and timely decisions when using CDSS. The HSUS has a very good reliability with global Cronbach’s alpha 0.914 and between 0.702 and 0.926 for the four subscales.ConclusionThe HSUS is a valid and reliable tool for usability testing of CDSS and early identification of usability issues that may cause medical adverse events.

Funder

Wellcome Trust

Health Innovation Challenge Fund

Department of Health and Social Care

Publisher

BMJ

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3